Frontiers in Environmental Chemistry

Revisiting loss-on-ignition temperatures for organic matter determination: implications for organic matter removal efficiency in microplastics’ quantification

Prithvendra Singh, Mrunal Bokade, Venkata Siva Naga Sai Goli, Devendra Narain Singh

Key points

From the paper's conclusion
  • The findings show a consistent and systematic overestimation of OM at 550 °C, with deviations of approximately 8%–12% compared to OM 440 °C .

Abstract

Digestion of organic matter (OM) in organic-rich solid matrices (ORSMs), such as landfill-mined soil-like fractions, landfill-mined residues, composts, and sediments, is an obligatory pre-treatment step in microplastics (MPs) quantification. In this regard, it is necessary to understand the optimal dosage of oxidizing agents for the digestion of OMs in the ORSMs. This optimal dosage is mainly based on Organic Matter Removal Efficiency (OMRE) of ORSMs, a widely adopted parameter in MP quantification studies. The OMRE is assessed through loss-on-ignition (LOI) of ORSMs at 550 °C, a commonly followed protocol, by comparing pre- and post-digestion mass losses. However, LOI at 550 °C overestimates the OM content in the ORSMs owing to the decomposition of clay minerals, viz., kaolinite, smectite. To address this anomaly/ambiguity, the present perspective study determined the OM using LOI at 440 °C (OM 440 °C ) and LOI at 550 °C (OM 550 °C ) for the above-mentioned ORSMs, quartz sand, kaolin, montmorillonite and bentonite. The findings show a consistent and systematic overestimation of OM at 550 °C, with deviations of approximately 8%–12% compared to OM 440 °C . It was realized that the overestimation of the OM at LOI 550 °C is predominantly due to the dihydroxylation of clay minerals and carbonate decomposition of inorganic mineral phases present in ORSMs. This perspective article establishes that the use of LOI 550 °C for the determination of OM consequently leads to its overestimation in ORSMs, thus contributing to the underestimation of OMRE. This anomaly introduces bias in establishing the appropriate dosage of the oxidizing agents and protocols for removing OM from ORSMs used in microplastic quantification. Furthermore, the present perspective article discusses the thermal processes governing the LOI measurements, at or above 550 °C, and its implications for OMRE and microplastics’ quantification.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers