Validation of late-night salivary cortisol for the diagnosis of Cushing’s syndrome and to explore its utility to differentiate between pituitary and ectopic ACTH-dependent Cushing syndrome

Khushboo Agarwal, Remya Rajan, Padmavathi Thirumakudalu Govindachari, Arun Jose, Nitin Kapoor, Kripa Elizabeth Cherian, Krishna Prabhu, Pamela Christudoss,

Observational · n=225

Key points

From the paper's conclusion
  • Further, in ACTH-dependent CS, an LNSC cut-off >1.015μg/dL may prompt early work-up for ECS.

Abstract

Purpose To evaluate the diagnostic performance of late-night salivary cortisol(LNSC) measured by second-generation electrochemiluminescence immunoassay(ECLIA-II) compared with liquid chromatography-tandem mass spectroscopy(LC-MS/MS) and to derive and validate a cut-off for the diagnosis of Cushing’s Syndrome(CS). Further, to assess the utility of LNSC in the differentiation of ACTH-dependent CS. Methods This diagnostic accuracy study was conducted in a tertiary care center in Southern India. In the prospective derivation cohort, LNSC was measured by ECLIA-II and LC-MS/MS, and the assays were compared. A diagnostic cut-off for LNSC using ECLIA-II for CS diagnosis was derived and it was validated in an independent retrospective validation cohort. LNSC values from all ACTH-dependent CS across both cohorts were analyzed to derive a cut-off that discriminated ectopic CS(ECS) from Cushing’s disease(CD). Results The derivation cohort comprised 43 patients with CS, 43 obese controls, and 42 normal-BMI controls, while the validation cohort comprised 225 patients (112 patients with CS and 113 controls). The Bland–Altman analysis showed poor agreement (bias: −0.069; 95% limits of agreement: −0.779 to 0.642) between the LNSC measured by ECLIA-II and LC-MS/MS. In the derivation cohort, an ECLIA-II LNSC cut-off of ≥0.135 μg/dL yielded sensitivity and specificity of ≥90% for CS diagnosis. This cut-off was revised to 0.204 μg/dL in the validation cohort, yielding a sensitivity of 96% and specificity of 90%. An LNSC cut-off of >1.015μg/dL predicted ECS with 88% sensitivity, 82% specificity, and a negative predictive value of 97%. Conclusion LNSC cut-off of 0.204μg/dL by ECLIA-II had excellent diagnostic accuracy for CS. Further, in ACTH-dependent CS, an LNSC cut-off >1.015μg/dL may prompt early work-up for ECS.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers