Indocyanine green alters intraoperative parathyroid hormone measurements: a timing-dependent effect.
Chia-Hsing Sung, Shih-Ming Huang, Ruei-Jhong Ye, Pei-Jhu Shih
Department of Laboratory Medicine, Chang Bing Show Chwan Memorial Hospital, Lugang, Taiwan. · Division of Thyroid Surgery, Chang Bing Show Chwan Memorial Hospital, Lugang, Taiwan.
Key points
From the paper's conclusion- Background Intraoperative indocyanine green (ICG) angiography and intraoperative parathyroid hormone (ioPTH) monitoring are widely used in thyroid surgery, yet analytical interference by ICG remains poorly characterized.
Abstract
BACKGROUND: Intraoperative indocyanine green (ICG) angiography and intraoperative parathyroid hormone (ioPTH) monitoring are widely used in thyroid surgery, yet analytical interference by ICG remains poorly characterized. This study quantitatively evaluated ICG-induced immunoassay distortions. METHODS: The study included paired in vitro spiking experiments (n = 6) and an in vivo thyroidectomy cohort (n = 6) with serial sampling during paused surgical dissection. Exploratory cross-platform analysis included paired perioperative samples from one patient and additional in vitro testing of three independent specimens. RESULTS: ICG caused significant false-positive elevations. In vitro, the median of individual fold-increases was 5.98 for PTH (1-84) and 3.34 for i-PTH (p = 0.031), producing an abnormal diagnostic ratio inversion (PTH (1-84)/i-PTH > 1.0). In vivo, measured levels peaked at 3 minutes post-injection (234.8% of baseline for 1-84 PTH; 146.1% for i-PTH) and approached baseline within 20 to 30 minutes (p > 0.05). CONCLUSION: Intravenous ICG can transiently distort ioPTH measurements and may lead to misleading interpretation during thyroid surgery. Whenever feasible, baseline ioPTH should be obtained before ICG administration. The observed return toward baseline within approximately 20 to 30 minutes is preliminary and requires validation before a post-ICG sampling interval can be recommended.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intraoperative Indocyanine Green Fluorescence Imaging in Thyroid Surgery: Technical Protocol, Evaluation Window and Interpretation Pitfalls - Single-Centre Experience in a Prospective Series of 42 Cases.Chirurgia (Bucharest, Romania : 1990) · 2026
- Indocyanine green fluorescence during total thyroidectomy: utility for predicting hypoparathyroidism and safety assessment.Langenbeck's archives of surgery · 2026
- Indocyanine green (ICG) guided thyroidectomy versus conventional thyroidectomy and the impact on parathyroid function preservation: an updated GRADE-assessed systematic review and meta-analysis.Langenbeck's archives of surgery · 2026
- Impact of Autofluorescence and Indocyanine Green Angiography on Post-Thyroidectomy Hypoparathyroidism: Multicenter Retrospective Comparative Cohort Study.World journal of surgery · 2026
- Association of combined near-infrared autofluorescence and indocyanine green angiography with immediate and permanent postoperative hypoparathyroidism after thyroid surgery: a propensity score-matched analysis.Updates in surgery · 2026
- Assessment of fluorescence interference in the basophil activation test: a case of indocyanine green-induced anaphylaxis.Journal of anesthesia · 2026