HalluciGuard-eye: knowledge graph-enhanced retrieval-augmented generation for hallucination detection and mitigation in ophthalmic multimodal large language models.
Ge Wu, Chong Ai, Weiqi Wu
Ophthalmic Center, The Second Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China.
Key points
From the paper's conclusion- Results HalluciGuard-Eye reduced hallucination rates by 42.2% compared with state-of-the-art medical multimodal large language models and achieved 91.6% factual accuracy for clinical entity recognition on EyePACS.
Abstract
BACKGROUND: Diabetic retinopathy (DR) is the leading cause of preventable blindness in working-age adults, yet scalable early detection is limited by the unreliability of AI-assisted screening. Multimodal large language models can interpret fundus photographs and support DR grading, but they frequently hallucinate - fabricating lesions or misclassifying referable DR - which directly threatens timely treatment and prevention of vision loss. We developed HalluciGuard-Eye to make AI-assisted DR assessment trustworthy. METHODS: HalluciGuard-Eye combines knowledge graph-enhanced retrieval-augmented generation with hierarchical hallucination detection. An Ophthalmic Clinical Knowledge Graph containing 47,832 medical entities and 156,294 semantic relationships was constructed from clinical guidelines and published literature. A dual-stream architecture uses a Visual-Semantic Alignment Module to verify cross-modal consistency and a Clinical Factuality Grounding Network to anchor generated content to reranked evidence. The Hierarchical Factuality Score assesses anatomical, pathological, and clinical-recommendation accuracy. The framework was evaluated on four public ophthalmic imaging benchmarks. RESULTS: HalluciGuard-Eye reduced hallucination rates by 42.2% compared with state-of-the-art medical multimodal large language models and achieved 91.6% factual accuracy for clinical entity recognition on EyePACS. For diabetic retinopathy grading, sensitivity was 89.6% and specificity was 92.1%, representing improvements of 2.4% and 2.7%, respectively, over MedRAG. In the component ablation, removing knowledge-graph retrieval lowered EyePACS HFS by 9.4 percentage points. Additional analyses yielded 87.6% critical-evidence recall@20, 89.2% lesion-location accuracy, and 88.9% sensitivity in a patient-clustered cohort. CONCLUSIONS: These results indicate that knowledge-grounded retrieval and hierarchical factuality assessment can reduce hallucinations while preserving diagnostic performance in ophthalmic multimodal language models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EyeGraph: A Multi-granularity Medical Vision-Language Foundation Model with Knowledge Graph Reasoning for Ophthalmic Interpretation.IEEE transactions on medical imaging · 2026
- LogicEye: Agent Driven Multimodal Dataset for Interpretable Ophthalmic DiagnosisarXiv · 2026
- A Text-Guided Lesion Mining Vision-Language Ordinal Classification Framework for Diabetic Retinopathy Grading.Journal of imaging · 2026
- MAGIC: Modality-Aware Gini Inspection for Clinical Hallucination Detection in LMMsarXiv · 2026
- Large language models as sources of diabetic retinopathy patient education: a comparative evaluation of safety, health information quality, and readability.Frontiers in public health · 2026
- A Visual Grounding Benchmark for Retinal OCT with Multimodal Large Language ModelsarXiv · 2026