Clinical and perioperative outcomes of computer-guided versus conventional plan-transfer workflows in orthognathic surgery for skeletal anterior open bite: a randomized controlled trial.
Ammar Abu Shama, Dirar Dibs
Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Al-Quds University, Jerusalem, Palestine.
Key points
From the paper's conclusion- No statistically significant between-group differences were detected in operative time, blood loss, or postoperative AOB. Computer-guided plan transfer was perceived to facilitate intraoperative handling, although this assessment was subjective. Given the small sample size and limited statistical power, the absence of statistically significant differences should not be interpreted as evidence of equivalence between the workflows. Larger adequately powered studies are warranted.
Abstract
INTRODUCTION: Skeletal anterior open bite (AOB) often requires orthognathic surgery. This study compared the clinical and perioperative outcomes of computer-guided and conventional plan-transfer workflows following virtual surgical planning. METHODS: Eighteen adults with skeletal AOB underwent virtual surgical planning and were subsequently randomized to computer-guided transfer of the established surgical plan using CAD/CAM guides (n = 9) or conventional model-surgery transfer using articulator-mounted casts and occlusal wafers (n = 9). Outcomes included intraoperative handling, operative time, blood loss, complications, healing, and AOB correction. RESULTS: Mean operative time was 6.0 ± 0.5 h versus 6.5 ± 0.6 h (p = 0.08), and blood loss was 450 ± 60 versus 520 ± 80 mL (p = 0.12) for the computer-guided and conventional groups, respectively. Intraoperative handling was perceived as easier with computer guidance, although this assessment was subjective. No major intraoperative complications occurred. Mean postoperative AOB was 1.33 ± 0.50 mm in both groups (p = 1.00). CONCLUSION: No statistically significant between-group differences were detected in operative time, blood loss, or postoperative AOB. Computer-guided plan transfer was perceived to facilitate intraoperative handling, although this assessment was subjective. Given the small sample size and limited statistical power, the absence of statistically significant differences should not be interpreted as evidence of equivalence between the workflows. Larger adequately powered studies are warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Surgical cutting and repositioning guides for minimally invasive orthognathic surgery: a retrospective comparative cohort study of bilateral sagittal split osteotomy.International journal of oral and maxillofacial surgery · 2026
- Clinical Outcomes of Virtual versus Conventional Planning in Orthognathic Surgery: A Systematic Review and Meta-analysis of Randomized Controlled Trials.Journal of maxillofacial and oral surgery · 2026
- Virtual Occlusion Accuracy in Orthognathic Surgery: Challenges and Critical Limitations in Segmental Maxillary Planning.Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons · 2026
- Accuracy of β-tricalcium phosphate gap patient-specific implants in chin osteotomies: a pilot validation study.International journal of oral and maxillofacial surgery · 2026
- Accuracy of maxillary positioning in semi-guided orthognathic surgery using 3D-printed cutting guides and bending plates: A retrospective study.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026
- Intraoperative Challenges of Patient-Specific Osteotomy Guides in Anterior Maxillary Osteotomy: A Case Report.Cureus · 2026