The autonomic-ventricular coherence index: a novel single-lead ECG method with acquisition-dependent discrimination.
Jayasree R, Chemmalar Selvi G
School of Computer Science Engineering and Information Systems, Vellore Institute of Technology Deemed to be University, Vellore, India.
Key points
From the paper's conclusion- These results show that AVCI's diagnostic performance depends on acquisition parameters, particularly sampling rate and recording duration.
Abstract
BACKGROUND: Autonomic regulation and the heart's electrical activity are both central to normal cardiac function, yet there is currently no direct way to capture the interaction between them from a standard ECG. This paper introduces the Autonomic-Ventricular Coherence Index (AVCI), a single-lead ECG method that measures the beat-to-beat spectral coherence between variability in RR intervals and variability in QRS area. METHODS: AVCI was developed and evaluated on 74 recordings from three PhysioNet databases (MIT-BIH Normal Sinus Rhythm, n = 18; BIDMC Congestive Heart Failure, n = 15; and MIT-BIH Arrhythmia, n = 41), with a further six recordings from the MIT-BIH Long-Term ECG Database used for preliminary independent validation. Coherence was integrated over the high-frequency band (0.15-0.40 Hz). Because the source databases differ in sampling rate and recording length, AVCI was examined both under each database's native recording conditions and after acquisition standardization, harmonizing all recordings to a common 128 Hz and 30-minute duration, additionally upsampling to 360 Hz for 30 min under uniform acquisition, and applying a two-tier duration-stratified framework. The analysis code is available at https://github.com/JayaSreejai/AVCI.git. RESULTS: Under native conditions, AVCI demonstrated a high capacity to distinguish between congestive heart failure and normal sinus rhythm (AUC 0.844). Like SDNN, it performed moderately in harmonized acquisition (NSR vs. CHF AUC 0.647; NSR vs. all-disease AUC 0.619). Under native conditions, machine learning models trained on balanced datasets performed well (KNN accuracy 79.5%, ROC-AUC 85.7, SVM accuracy 79.0%, ROC-AUC 83.0), whereas under harmonized conditions, they produced average results. R-peak identification was consistent across QRS windows and accurate (F1 0.892). These results show that AVCI's diagnostic performance depends on acquisition parameters, particularly sampling rate and recording duration. CONCLUSIONS: AVCI is a practical and understandable measure of autonomic-ventricular coupling from a single ECG lead. Combined with machine learning, it offers a promising path toward more robust and explainable cardiovascular diagnostics. Standardized acquisition protocols are key to reliable clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inter-Lead RRI Agreement Between Lead I and Lead II Across Diagnostic ECG Categories: Pilot Evidence for Wearable HRV MonitoringApplied Sciences · 2026
- Quantitative QRS voltage variability for differentiating fast atrial fibrillation from supraventricular tachycardia: a large ECG dataset studyEuropean Heart Journal · 2026
- Frequency and outcomes of arrhythmias and conduction system abnormalities using real-world handheld single-lead ECGs: A VITAL-AF trial analysisEuropean Heart Journal · 2026
- Artificial Intelligence-Enabled Electrocardiography Model for Left Ventricular Systolic and Diastolic Dysfunction Predict Incident Atrial Fibrillation in Patients with Sinus Rhythm: A Time-Dependent Analysis.Diagnostics (Basel, Switzerland) · 2026
- Ultra-Short HRV from holter ECG cannot replace 5-Minute HRV for short-term AF onset predictionEuropean Heart Journal · 2026
- Wearable device derived electrocardiographic age and its association with atrial fibrillationnpj Digital Medicine · 2026