Geometry- and dynamics-based generation and imputation of neonatal pose sequences: linear, angular, inertia-based, and LSTM models
Syed Taimoor Hussain Shah, Syed Adil Hussain Shah, Janet Pigueiras-del-Real, Konstantinos Panagiotopoulos, Syed Baqir Hussain Shah, Angelo Di Terlizzi, Isabel Benavente-Fernández, Simón P. Lubián-López,
Key points
From the paper's conclusion- Broader validation across diverse neonatal populations remains necessary.
Abstract
Introduction Limited neonatal motion data make it difficult to develop and evaluate methods for generating infant pose sequences. A key challenge is maintaining movement dynamics and body geometry when extending short observed pose sequences. Methods In this proof-of-concept computational study, we compared four algorithms for deterministic pose continuation: PoseLineoTrack, PoseAnguTrack, PoseInertiTrack, and PoseLSTMNet. Imputation was examined as an additional application. Pose datasets from five independent male infants were obtained from the NeoVault repository. Two image-relative datasets and a separate three-infant hip-centered replication were evaluated under distinct protocols. The clinical protocol used training-only normalization and separate validation partitions, while public MINI-RGBD models were fitted separately. Following a finite observed seed, all subsequent coordinates were generated autonomously over 1–60 frames. Additional analyses examined uncertainty, parameter sensitivity, temporal coordination, dynamical baselines, static controls, masked reconstruction, and reference-matched continuations extending to 2,500 frames. Results Among the four algorithms, PoseInertiTrack achieved the lowest 30-frame cumulative normalized RMSE on Subject 2 (0.2724) and across six public test sequences (0.4307). However, its Subject 2 distal speed and variance ratios were 0.353 and 0.568, respectively, indicating attenuated movement. In the separate hip-centered replication, PoseLSTMNet achieved the lowest RMSE on both test infants (0.2632 and 0.3351), but the corresponding speed ratios (0.098 and 0.063) indicated substantial movement attenuation. Additional analyses distinguished coordinate agreement from realistic movement synthesis and characterized the limitations of numerical accuracy. Discussion This study provides a reproducible comparison of neonatal pose-generation algorithms while identifying important movement-fidelity limitations. The small all-male cohort, tracker-derived references, development-stage inspection, and absence of clinical or augmentation validation constrain generalizability. Broader validation across diverse neonatal populations remains necessary.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Infant Movement Classification Using Pose-Based Motion Features and a Learned Hybrid k-Nearest Neighbor Model.Bioengineering (Basel, Switzerland) · 2026
- SynPanZ: A Synthetic Dataset to Improve Multi-Animal Pose Estimation in Chimpanzees (Pan troglodytes)arXiv · 2026
- An Automated Framework for Pose-Sequence Analysis of Spontaneous Movements in Preterm Infants.IEEE open journal of engineering in medicine and biology · 2026
- Deep Imputation for Skeleton data (DISK) for behavioral scienceNature Methods · 2025
- Biomechanically Grounded Prediction of Selective Motor Control and Clinical Outcomes from Infant VideoarXiv · 2026
- Automatic pose estimation in newborn infants: Lessons from the Baby Grow studyBehavior Research Methods · 2026