Mitral valve surgery after failed transcatheter edge-to-edge repair: eight-year survival and functional outcomes from two centers
Lilly Ilcheva Burger, Marta Ambrus, Can Keskinaslan, Rasha Boulos, Petar Risteski, Igor Tudorache, Nestoras Papadopoulos, Hector Rodriguez Cetina Biefer,
Key points
From the paper's conclusion- Conclusion Mitral valve surgery after failed TEER was performed with low in-hospital mortality but substantial morbidity, and repair was achieved in only one in nine patients.
Abstract
Background Transcatheter edge-to-edge repair (TEER) is increasingly offered to patients at low and intermediate surgical risk, yet the outcomes of mitral valve surgery after failed TEER remain poorly defined, and long-term data are scarce. Methods We retrospectively analyzed all consecutive patients who underwent mitral valve surgery after failed TEER at two Swiss centers between January 2017 and April 2024. The primary endpoint was Kaplan–Meier survival; secondary endpoints were perioperative complications and changes in New York Heart Association ( N YHA) class, left ventricular ejection fraction (LVEF) and mitral regurgitation (MR) grade, assessed by transthoracic echocardiography before discharge after TEER and before surgery. Cause-specific mortality was analyzed with competing-risk methods. Results Thirty-five patients were included (median age 76 years at surgery; primary MR in 29, 82.9%). Most had been discharged after TEER with non-severe MR (23/35, 65.7%) and underwent surgery more than 30 days later (23/35, 65.7%); severe MR was present in 12 patients (34.3%) at discharge after TEER and in 28 (80.0%) before surgery. Median EuroSCORE II rose from 2.9 (1.6–3.8) before TEER to 6.3 (3.7–17.0) before surgery ( p < 0.001). Repair was achieved in 4 patients (11.4%). In-hospital mortality was 2.9%, but morbidity was substantial: pneumonia occurred in 28.6%, renal replacement therapy in 17.1% and tracheostomy in 11.4%, and median hospital stay was 15 days. Kaplan–Meier survival was 91.4%, 72.5% and 59.0% at 1, 3 and 5 years (32, 21 and 12 at risk); the 8-year estimate of 40.2% rests on a single patient at risk and is exploratory. Eight of 14 deaths were cardiac. No surviving patient had severe MR or NYHA class III–IV at one year. Conclusion Mitral valve surgery after failed TEER was performed with low in-hospital mortality but substantial morbidity, and repair was achieved in only one in nine patients. Most patients came to surgery after later deterioration rather than immediate procedural failure. Durability, rather than acute procedural success, should therefore inform the choice of TEER, particularly in younger and lower-risk patients, and surveillance after TEER should extend beyond the index hospitalization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Failure After Mitral Transcatheter Edge-to-Edge Repair Mechanisms, Outcomes, and Management.Structural heart : the journal of the Heart Team · 2026
- Pulmonary arterial systolic pressure evolution after transcatheter edge-to-edge mitral valve repair and its association with outcomesEuropean Heart Journal · 2026
- Durability of Mitral Valve Transcatheter Edge-to-Edge RepairJACC: Cardiovascular Interventions · 2026
- Persistent Severe Tricuspid Regurgitation After Mitral Transcatheter Edge-to-Edge Repair: Prognostic Implications of Guideline-Based Eligibility for Transcatheter Tricuspid Valve InterventionStructural Heart · 2026
- 6 months follow-up after mitral transcatheter edge-to-edge repair: clinical and procedural determinates that may affect residual mitral regurgitationEuropean Heart Journal · 2026
- Combined transcatheter mitral and tricuspid edge-to-edge repair or tricuspid edge-to-edge repair alone in moderate mitral regurgitation: a propensity-matched analysisEuropean Heart Journal · 2026