Temporal leakage and evaluation-boundary effects in heart failure mortality prediction: a unified reanalysis of the 299-patient heart failure clinical records dataset
Yinuo Diao, Kuikui Zhang, Wenzeng Wang
Key points
From the paper's conclusion- Background The 299-patient Heart Failure Clinical Records dataset is widely used for mortality prediction, yet reported performance varies substantially.
Abstract
Background The 299-patient Heart Failure Clinical Records dataset is widely used for mortality prediction, yet reported performance varies substantially. Differences in prediction time, follow-up handling, resampling, and data splitting may materially affect apparent model performance. Objective To examine how prediction-time alignment, modelling procedures, and evaluation boundaries influence performance estimates on this shared benchmark, using a targeted methodological audit and harmonized reanalysis of representative modelling configurations. Methods Four representative modelling routes were evaluated using the same dataset. Admission-time classification used 11 baseline variables and stratified 10-fold cross-validation, with applicable resampling and feature-construction procedures restricted to the training data. A parsimonious random forest using ejection fraction and serum creatinine was also assessed. Follow-up duration was excluded from baseline classification and retained for time-to-event analyses. Sensitivity analyses examined follow-up-duration inclusion and changes in preprocessing boundaries. Patient-level bootstrap confidence intervals, repeated-seed analyses, calibration, and exploratory decision-curve analysis were additionally performed. Results Fold-mean AUROCs across the four 11-variable classification configurations ranged from 0.724 to 0.784. The two-feature random forest achieved a pooled out-of-fold AUROC of 0.779 (95% CI, 0.721–0.832), with a paired difference of 0.007 (95% CI, −0.047 to 0.062) from the 11-variable random-forest comparator. Adding follow-up duration increased fold-mean AUROC by 0.121–0.135 within matched predictor sets. The two-feature model retained substantial discrimination but showed limited calibration, with a calibration slope of 0.234 (95% CI, 0.154–0.404). Preprocessing sensitivity analyses also produced substantial variation in apparent performance. Conclusions Prediction-time alignment and evaluation procedures materially influenced performance estimates on this benchmark. Similar discrimination did not imply comparable probability calibration or equivalent patient-level risk estimates. Clinical interpretation therefore requires explicit definition of prediction time, outcome horizon, model implementation, and evaluation procedures, followed by validation in independent contemporary cohorts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine learning-based prediction of in-hospital and post-discharge mortality in heart failure: an international retrospective study with cross-endpoint transferability analysis.Frontiers in digital health · 2026
- Machine learning–based identification of mortality risk factors in hospitalized heart failure patients: a multicenter real-world studyEuropean Heart Journal · 2026
- CONFIDENT-HFpEF: a machine learning-based risk stratification for mortality and hospitalization using multimodal real-world dataESC Heart Failure · 2026
- Prediction of Heart Failure based on Multimodal Data from MIMIC-IVCurrent Directions in Biomedical Engineering · 2026
- "Mortality Prediction in Heart Failure using Explainable AI: Development and Validation of the EXACT-HF Model in a Nationwide Multi-Ethnic Asian Cohort"medRxiv · 2026
- Predictive Modeling of Mortality Risk in Heart Failure Patients Using Logistic Regression Analysis of Clinical FeaturesEngineering Frontiers · 2025