Angiography-derived versus wire-based fractional flow reserve for guiding coronary revascularization: a meta-analysis of randomized controlled trials.
Peng-Yu Zhong, Qing-Yi Yang, Liu Lei, Lin He, Wei Ni
Department of Cardiology, Beijing Anzhen Nanchong Hospital of Capital Medical University & Nanchong Central Hospital (The Second Clinical College of North Sichuan Medical College), Nanchong, Sichuan, China. · The Second Clinical College of North Sichuan Medical College, Nanchong, Sichuan, China.
Key points
From the paper's conclusion- Further large-scale trials with extended follow-up are needed to clarify the long-term implications of this revascularization pattern.
Abstract
BACKGROUND: Invasive pressure-wire-based fractional flow reserve (FFR) is the reference standard for physiology-guided coronary revascularization, yet it requires pressure-wire equipment and adenosine-induced hyperemia. Angiography-derived FFR enables functional assessment solely from coronary angiograms, while quantitative pooled evidence from patient-level randomized controlled trials (RCTs) remains limited. METHODS: We searched PubMed, Cochrane Library, Embase and Web of Science Core Collection for eligible RCTs comparing angiography-derived FFR-guided versus wire-based FFR-guided revascularization. The primary endpoint was major adverse cardiovascular events (MACE). Pooled risk ratios or mean differences with 95% confidence intervals were calculated. GRADE assessment and trial sequential analysis (TSA) were performed, and publication bias was evaluated by funnel-plot inspection. RESULTS: Four RCTs involving 6,542 participants were included. No significant difference in MACE was observed between groups (RR 1.07, 95%CI 0.91-1.27). All-cause mortality, cardiac mortality, recurrent myocardial infarction, unplanned revascularization and stent thrombosis were also comparable. Angiography-derived FFR was associated with higher patients-level PCI rate (RR 1.24, 95%CI 1.15-1.33), lesion-level PCI rate (RR 1.24, 95%CI 1.18-1.31) and shorter procedural time (MD -4.09 min, 95%CI -5.76 to -2.43). TSA showed insufficient sample size for most hard clinical endpoints. GRADE certainty varied across endpoints, procedural outcomes were rated high-certainty, while most clinical outcomes were of moderate certainty and stent thrombosis of low certainty. CONCLUSIONS: Relative to wire-based FFR, angiography-derived FFR showed no statistically significant difference in ischaemic-driven clinical outcomes and procedural duration. However, it may increase the likelihood of undergoing PCI. Further large-scale trials with extended follow-up are needed to clarify the long-term implications of this revascularization pattern. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/PROSPERO/, CRD420261479620.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical outcomes of angiography-derived fractional flow reserve compared with invasive and imaging-guided PCI: a network meta-analysisEuropean Heart Journal · 2026
- Angiography-Derived Versus Wire-Based Physiological Assessment of Intermediate Coronary Lesions-A Non-Inferiority Meta-Analysis and Systematic Review.Journal of cardiovascular development and disease · 2026
- Angiography-Derived Fractional Flow Reserve to Guide PCINew England Journal of Medicine · 2026
- Angiography-Derived vs Wire-Based Physiological Assessment in Coronary Artery Disease: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.Critical pathways in cardiology · 2026
- Angiography-Based Physiology to Guide Coronary RevascularizationNew England Journal of Medicine · 2026
- Quantitative flow ratio versus fractional flow reserve: 2-year follow-up of the FAVOR III Europe trialEuroIntervention · 2026