Supra-annular sizing method at the LIGHT plane in Sievers type 0 bicuspid aortic valve
Gianluca Ricchetti, Vittorio Romano, Barbara Bellini, Ciro Vella, Filippo Russo, Marco Bruno Ancona, Luca Angelo Ferri, Matteo Montorfano
Key points
From the paper's conclusion- Our study aims to introduce and evaluate a novel supra-annular sizing approach for type 0 BAV based on the identification of the “LIGHT” (Level of Implantation at the neo- hinGe Height in Type 0 BAV) plane defined by native leaflet dynamics and possibly representing the level of maximal prosthesis-leaflet interaction.
Abstract
Background As transcatheter aortic valve replacement (TAVR) expands to younger and lower-risk populations, the proportion of patients with bicuspid aortic valve (BAV) anatomy undergoing transcatheter treatment is increasing. In Sievers type 0 BAV, due to the peculiar anatomy, the conventional annular sizing may fail to identify the anchoring and sealing level, contributing to worse clinical outcomes after TAVR in comparison to tricuspid anatomy. Our study aims to introduce and evaluate a novel supra-annular sizing approach for type 0 BAV based on the identification of the “LIGHT” (Level of Implantation at the neo- hinGe Height in Type 0 BAV) plane defined by native leaflet dynamics and possibly representing the level of maximal prosthesis-leaflet interaction. Methods Eight consecutive patients with type 0 BAV and severe aortic stenosis underwent TAVR using supra-annular self-expanding valves sized according to the perimeter measured at the LIGHT plane. Procedural and in-hospital outcomes were assessed according to the Valve Academic Research Consortium- 3 (VARC-3) criteria. Results Sizing based on the LIGHT plane perimeter resulted in prosthesis downsizing in 5 patients (62.5%). Technical success and device success were achieved in all patients (100%). There were no deaths, annular ruptures, strokes, or major vascular complications. The median post-procedural transvalvular gradient was 8.0 mmHg (5.5–10.5). One patient (12.5%) required permanent pacemaker implantation. Conclusions The LIGHT plane sizing approach for TAVR in type 0 BAV was feasible and safe in this preliminary experience. This anatomy-driven approach may improve TAVR outcomes in this challenging subset.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Balloon-expandable valves vs self-expanding valves for transcatheter aortic valve replacement in bicuspid aortic valve stenosis: a meta-analysisEuropean Heart Journal · 2026
- Influence of ascending aorta diameter on short- and long-term clinical outcomes after transcatheter aortic valve implantation for bicuspid aortic valve stenosisEuropean Heart Journal · 2026
- Outcomes of transcatheter aortic valve replacement in patients with bicuspid aortic valveEuropean Heart Journal · 2026
- Self-expanding vs. balloon-expandable valves in small annulus patients undergoing transcatheter aortic valve implantationEuropean Heart Journal · 2026
- Impact of self-expanding valve selection on hemodynamics and clinical outcomes in patients with borderline annular dimensions for balloon-expandable valve: insights from the multicenter-TAVI registryEuropean Heart Journal · 2026
- TAVI for Bicuspid Aortic Valve: Addressing Technical Challenges and Optimizing OutcomesJournal of Clinical Medicine · 2025