Frontiers in Cardiovascular Medicine

Supra-annular sizing method at the LIGHT plane in Sievers type 0 bicuspid aortic valve

Gianluca Ricchetti, Vittorio Romano, Barbara Bellini, Ciro Vella, Filippo Russo, Marco Bruno Ancona, Luca Angelo Ferri, Matteo Montorfano

Key points

From the paper's conclusion
  • Our study aims to introduce and evaluate a novel supra-annular sizing approach for type 0 BAV based on the identification of the “LIGHT” (Level of Implantation at the neo- hinGe Height in Type 0 BAV) plane defined by native leaflet dynamics and possibly representing the level of maximal prosthesis-leaflet interaction.

Abstract

Background As transcatheter aortic valve replacement (TAVR) expands to younger and lower-risk populations, the proportion of patients with bicuspid aortic valve (BAV) anatomy undergoing transcatheter treatment is increasing. In Sievers type 0 BAV, due to the peculiar anatomy, the conventional annular sizing may fail to identify the anchoring and sealing level, contributing to worse clinical outcomes after TAVR in comparison to tricuspid anatomy. Our study aims to introduce and evaluate a novel supra-annular sizing approach for type 0 BAV based on the identification of the “LIGHT” (Level of Implantation at the neo- hinGe Height in Type 0 BAV) plane defined by native leaflet dynamics and possibly representing the level of maximal prosthesis-leaflet interaction. Methods Eight consecutive patients with type 0 BAV and severe aortic stenosis underwent TAVR using supra-annular self-expanding valves sized according to the perimeter measured at the LIGHT plane. Procedural and in-hospital outcomes were assessed according to the Valve Academic Research Consortium- 3 (VARC-3) criteria. Results Sizing based on the LIGHT plane perimeter resulted in prosthesis downsizing in 5 patients (62.5%). Technical success and device success were achieved in all patients (100%). There were no deaths, annular ruptures, strokes, or major vascular complications. The median post-procedural transvalvular gradient was 8.0 mmHg (5.5–10.5). One patient (12.5%) required permanent pacemaker implantation. Conclusions The LIGHT plane sizing approach for TAVR in type 0 BAV was feasible and safe in this preliminary experience. This anatomy-driven approach may improve TAVR outcomes in this challenging subset.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Supra-annular sizing method at the LIGHT plane in Sievers type 0 bicuspid aortic valve — Science Skim