Case Report: Angiography-guided transvenous single-chamber pacemaker implantation in mirror-image dextrocardia with congenitally corrected transposition of the great arteries.
Junda Cao, Qin Ao, Jin Ma, Ji Sun
Jiujiang City Key Laboratory of Cell Therapy, Department of Cardiovascular Medicine, The First Hospital of Jiujiang City, Jiujiang, China.
Key points
From the paper's conclusion- Conclusion This case describes a structured approach to conventional transvenous pacemaker implantation in mirror-image dextrocardia with ccTGA.
Abstract
BACKGROUND: Mirror-image dextrocardia with situs inversus is uncommon. Transvenous permanent pacemaker implantation is technically demanding when it coexists with congenitally corrected transposition of the great arteries (ccTGA), because venous access, atrioventricular valve crossing, and fluoroscopic lead orientation may differ from usual anatomy. CASE PRESENTATION: A 61-year-old man was admitted with recurrent dizziness and palpitations for 5 years; his symptoms had worsened during the preceding 2 weeks. Preoperative 12-lead electrocardiography showed atrial fibrillation with a slow ventricular response. Twenty-four-hour Holter monitoring documented 707 pauses longer than 2.0 s, with a longest R-R interval of 6.13 s. Echocardiography confirmed mirror-image dextrocardia, situs inversus, and ccTGA. A single-chamber permanent pacemaker was implanted through the right axillary vein. Posteroanterior fluoroscopy defined the right-sided cardiac silhouette; right axillary venography guided venous puncture; right atrial angiography identified the morphologic mitral annular plane; and multi-projection fluoroscopy was used to confirm the final ventricular lead position in the high mid-septal region of the morphologic left ventricle. The procedure lasted 56 min and had no acute complications. At 6-month outpatient follow-up, standard 12-lead electrocardiography, 24-hour Holter monitoring, formal device interrogation, and transthoracic echocardiography showed stable pacing, preserved ventricular performance, and no device-related complication; the paced QRS duration was 144 ms and the pacing burden was 99.8%. During telephone follow-up in June 2026, approximately 1 year after implantation, the patient reported no discomfort. CONCLUSION: This case describes a structured approach to conventional transvenous pacemaker implantation in mirror-image dextrocardia with ccTGA. In this patient, venography, chamber angiography, and targeted fluoroscopic views reduced procedural uncertainty, and follow-up through 1 year showed clinical stability without recognized complications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-Chamber Leadless Pacemaker Implantation in Dextrocardia With Situs Inversus.JACC. Case reports · 2026
- Left-sided surgical approach for tricuspid valve replacement in congenitally corrected transposition of the great arteries with dextrocardia and situs inversus totalis: A case report.Journal of cardiothoracic surgery · 2026
- Affordable and Efficient Anatomy Mapping for LBBAP in Dextrocardia With Complete Heart Block.Pacing and clinical electrophysiology : PACE · 2026
- Guiding Pacemaker Implantation With Multimodality Imaging in an Adult With Ventricular Septal Defect.JACC. Case reports · 2026
- Ablation in Dextrocardia With Interrupted Inferior Vena Cava and Azygos Continuation to Coronary Sinus.JACC. Case reports · 2026
- Left bundle branch-optimized cardiac resynchronization therapy in a dextrocardia patient: a case report.European heart journal. Case reports · 2026