Efficacy and safety of low-power (20 W) catheter ablation for typical atrioventricular nodal reentrant tachycardia: a prospective multicenter study.
Lae-Young Jung, Chang Hee Kwon, In Geol Song, Ji Hyun Lee, Minsu Kim
Division of Cardiology, Jeonbuk National University Hospital and Jeonbuk National University Medical School, Jeonju, Republic of Korea. · Division of Cardiology, Department of Internal Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Republic of Korea.
Key points
From the paper's conclusion- Conclusion An initial 20 W ablation strategy provides high efficacy with a favorable safety profile and no permanent AV block observed in this cohort.
Abstract
BACKGROUND: Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common supraventricular tachycardia. Although catheter ablation is the definitive treatment, atrioventricular (AV) block requiring permanent pacemaker implantation remains a major safety concern. OBJECTIVE: To evaluate the efficacy and safety of a low-power (20 W) slow pathway ablation strategy for typical AVNRT. METHODS: In this prospective multicenter study, 203 consecutive patients (mean age 54.4 ± 17.3 years; 59.6% women) underwent slow pathway ablation initiated at 20 W, with power escalation as needed. Variables associated with requiring higher power were analyzed using univariable and multivariable logistic regression. RESULTS: Initial success at 20 W was achieved in 170 patients (83.7%); 33 patients (16.3%) required higher power, with an overall acute success rate of 99.5%. Compared with patients who achieved success at 20 W, those requiring higher power were younger and had higher pre-ablation heart rates. On univariable analysis, younger age [odds ratio [OR] 0.66 per 10-year increase, 95% confidence interval [CI] 0.54-0.83; p < 0.001] and higher pre-ablation heart rate (OR 1.88 per 10-bpm increase, 95% CI 1.30-2.73; p < 0.001) were associated with the need for higher power. Transient AV block occurred in 1.9% of patients, and no cases of permanent AV block (0%, 95% CI 0%-1.8%) or pacemaker implantation were observed. During 18.3 ± 4.1 months of follow-up, recurrence occurred in two patients (0.9%). CONCLUSION: An initial 20 W ablation strategy provides high efficacy with a favorable safety profile and no permanent AV block observed in this cohort. Younger age and a higher baseline heart rate predicted the need for power escalation, supporting an initial low-power approach for AVNRT ablation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Radiofrequency ablation versus cryotherapy for pediatric atrioventricular nodal re-entrant tachycardia: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Pseudo-focal retrograde atrial activation due to undetected slow pathway potentials during atypical atrioventricular nodal reentrant tachycardiaEuropean Heart Journal · 2026
- Accurate Diagnosis of Atrioventricular Nodal Reentrant Tachycardia With Very Short His‐Atrial Interval and Earliest Activation in the Proximal Coronary SinusJournal of Cardiovascular Electrophysiology · 2026
- Empirical slow-pathway ablation in suspected but non-inducible AVNRT: a scoping reviewFrontiers in Cardiovascular Medicine · 2026
- Relationship between CARTO late annotation mapping and successful cryoablation sites in typical atrioventricular nodal reentrant tachycardiaEuropean Heart Journal · 2026
- Conventional Atrioventricular Nodal Reentrant Tachycardia Ablation: 16-Year Acute Outcomes and Pacemaker Requirement.Pacing and clinical electrophysiology : PACE · 2026