Frontiers in Cardiovascular Medicine

Pericoronary fat attenuation index and TyG index improve CCTA-based diagnosis of in-stent restenosis: a cross-sectional study

Bing Liu, Xu Li, Mengyu Chen

Observational · n=240

Key points

From the paper's conclusion
  • Objective This study investigated the associations of the pericoronary fat attenuation index (FAI) and triglyceride–glucose (TyG) index with in-stent restenosis (ISR) in patients with coronary artery disease (CAD) following stent implantation and evaluated the diagnostic value of combining these markers with coronary computed tomography angiography (CCTA).

Abstract

Objective This study investigated the associations of the pericoronary fat attenuation index (FAI) and triglyceride–glucose (TyG) index with in-stent restenosis (ISR) in patients with coronary artery disease (CAD) following stent implantation and evaluated the diagnostic value of combining these markers with coronary computed tomography angiography (CCTA). Methods A total of 240 patients with previous stent implantation who underwent CCTA and coronary angiography (CAG) within one month were included. Pericoronary FAI was quantified from CCTA images using a semiautomated analysis system, and the TyG index was calculated. Patients were classified into ISR and non-ISR groups according to CAG findings. Clinical and imaging characteristics were compared between the groups. Patient-level associations with ISR were assessed using binary logistic regression, whereas stent-level analyses employed generalized estimating equations (GEE) to account for within-patient clustering. Receiver operating characteristic (ROC) curve analysis was used to evaluate the discriminative performance of CCTA, FAI and the TyG index, individually and in combination. Results At the patient level, the ISR group had a higher TyG index (8.83 vs. 8.52, p = 0.006) and higher FAI around the right coronary artery (RCA) (−80.8 vs. −83.4 HU, p = 0.014). At the stent level, pre-stent FAI (−79.1 vs. −81.7 HU, p = 0.025), peri-stent FAI (−82.3 vs. −86.6 HU, p < 0.001), and the TyG index (8.85 vs. 8.58, p = 0.006) were higher in the ISR group. In multivariable GEE analysis, peri-stent FAI (OR = 1.063, p = 0.001) and the TyG index (OR = 1.685, p = 0.009) were independently associated with ISR. The area under the ROC curve (AUC) increased from 0.639 for CCTA alone to 0.734 for CCTA combined with peri-stent FAI and the TyG index ( p < 0.001). Conclusion The TyG index and peri-stent FAI were independently associated with ISR. A diagnostic model combining these two markers with CCTA demonstrated better discrimination than CCTA alone.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers