Frontiers in cardiovascular medicine

Peripheral microvascular function and in-stent late lumen loss after percutaneous coronary intervention: a retrospective cohort study with an exploratory analysis by implanted stent diameter.

Hangyeol Kim, Hyun Sung Joh, Woo-Hyun Lim, Hack-Lyoung Kim, Sang-Hyun Kim, Jae-Bin Seo

Department of Internal Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea. · Cardiovascular Center, Seoul National University Boramae Medical Center, Seoul, Republic of Korea.

Observational · n=132

Key points

From the paper's conclusion
  • Subgroup analyses by implanted stent diameter (≤2.75 versus >2.75 mm) and diabetes were exploratory.

Abstract

INTRODUCTION: Peripheral microvascular endothelial function measured by the reactive hyperemia index (RHI) with EndoPAT predicts cardiovascular outcomes, and post-procedural RHI has been associated with binary in-stent restenosis. Whether pre-procedural RHI relates to in-stent late lumen loss (LLL) measured by quantitative coronary angiography (QCA) after percutaneous coronary intervention (PCI), and whether any association depends on device caliber, has not been established. METHODS: We retrospectively analyzed 132 patients who underwent EndoPAT before PCI (index PCI 2009-2016). The primary endpoint was in-stent LLL at follow-up angiography (n = 91; median follow-up 9.4 months). Because in-stent LLL was highly skewed, the primary analysis used Spearman correlation and a robust (HC3) multivariable regression adjusting for age, diabetes, hypertension, number of diseased vessels, and pre-PCI minimal lumen diameter. Pre-specified sensitivity analyses included multiple imputation (MICE, m = 20) for missing follow-up and lesion-level generalized estimating equations (GEE). Subgroup analyses by implanted stent diameter (≤2.75 versus >2.75 mm) and diabetes were exploratory. RESULTS: RHI showed only a borderline inverse correlation with in-stent LLL (ρ = -0.19, p = 0.07) and was not independently associated with it (adjusted β = -0.11, 95% CI -0.39 to +0.18, p = 0.45); multiple imputation (β = -0.08) and GEE (β = -0.07) were concordant, and no correlation survived false-discovery-rate correction. Stratification by native reference vessel diameter showed no association, whereas stratification by implanted stent diameter revealed an inverse RHI-LLL correlation confined to small-diameter stents (≤2.75 mm, n = 33; ρ = -0.375, p = 0.032) but not larger stents (ρ = -0.055). However, the stent-diameter × RHI interaction was not significant (p = 0.48), so this caliber-dependent signal is hypothesis-generating and tracks the achieved implanted caliber rather than the native reference vessel. Inflammation explained neither result. High-sensitivity C-reactive protein (hs-CRP) was unrelated to RHI (ρ = -0.02) and to in-stent LLL (ρ = +0.15), and adding it to the primary model left the RHI estimate unchanged. Small-caliber recipients had similar hs-CRP but more diabetes (57.6% versus 27.6%, p = 0.009) and worse renal function (p = 0.008), indicating a higher-risk phenotype rather than a pure caliber stratum. DISCUSSION: Pre-procedural EndoPAT RHI was not independently associated with in-stent LLL. The exploratory signal confined to small-caliber stents is hypothesis-generating and requires prospective, device-caliber-stratified validation pairing pre- with post-procedural RHI.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Peripheral microvascular function and in-stent late lumen loss after percutaneous coronary intervention: a retrospective cohort study with an exploratory analysis by implanted stent diameter — Science Skim