Trajectories of kinesiophobia over the first six months after cardiac pacemaker or defibrillator implantation: clinical, psychological, and rehabilitation predictors and their relation to functional capacity.
Chunli Zhang, Xiaoping Guo
Department of Cardiology, The 980th Hospital of the Joint Logistic Support Force of the Chinese People's Liberation Army (Bethune International Peace Hospital), Shijiazhuang, Hebei, China.
Key points
From the paper's conclusion- We aimed to identify distinct trajectories of kinesiophobia during the first six months after implantation, to relate them to functional capacity, and to identify baseline factors that predict an unfavourable course.
Abstract
OBJECTIVE: Kinesiophobia, an excessive fear of physical movement, is common after implantation of a cardiac pacemaker or implantable cardioverter defibrillator and may limit rehabilitation and recovery. Because fear of movement changes over time, a single measurement cannot capture how it evolves. We aimed to identify distinct trajectories of kinesiophobia during the first six months after implantation, to relate them to functional capacity, and to identify baseline factors that predict an unfavourable course. METHODS: In a single centre retrospective cohort based on routinely collected structured follow-up data, 160 consecutive patients undergoing first implantation of a pacemaker or defibrillator were assessed 24 to 48 h after the procedure and again at 1, 3, and 6 months. Kinesiophobia was measured with the Tampa Scale for Kinesiophobia Heart and functional capacity with the six-minute walk distance. Group-based trajectory modelling identified latent trajectories. Baseline characteristics were compared across classes, and multinomial logistic regression identified independent predictors of class membership. RESULTS: Mean kinesiophobia fell from 42.9 to 35.2 over six months, and the proportion above the high-fear threshold fell from 76.2% to 37.5%. Three trajectories emerged: low and declining (28.8%), moderate and declining (45.0%), and high and persistent (26.2%). The persistent group stayed above the clinical threshold throughout and walked the shortest distance at every visit. Compared with the low group, independent predictors of a persistent course were higher depression (odds ratio 2.26), higher anxiety (1.68), lower exercise self-efficacy (0.89), shorter baseline walk distance (0.55 per 10 m), and absence of exercise guidance (0.04 for having received guidance). CONCLUSION: Kinesiophobia after device implantation follows three trajectories, separated mainly by the overall level of fear. About one quarter of patients remain persistently fearful and physically limited; they can be identified early by distress, low self-efficacy, poor functional capacity, and lack of exercise guidance. Early screening and targeted exercise-based rehabilitation are warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Trajectories of Kinesiophobia and Influencing Factors in Patients With Acute Myocardial Infarction.Clinical nursing research · 2026
- Prevalence of Kinesiophobia and Associated Factors Among Patients After Percutaneous Coronary Intervention: A Multicenter Cross-Sectional Study.Nursing open · 2026
- Fear of movement in cardiac care: how patients and professionals define cardiac kinesiophobiaEuropean Heart Journal · 2026
- Analysis of risk factors for kinesiophobia after coronary artery bypass grafting and construction of a nomogram prediction model.Frontiers in cardiovascular medicine · 2026
- Acute Pain Trajectory Phenotypes are Associated with Kinesiophobia and Functional Recovery in Surgical/Trauma ICU Patients: A 5-Year Retrospective Cohort Study Using a PERMA-Informed Framework.Journal of pain research · 2026
- Latent profile analysis and influencing factors of kinesiophobia among young and middle-aged patients with coronary heart diseaseFrontiers in Medicine · 2026