Efficacy and safety of conscious/deep sedation versus general anesthesia in pulsed field ablation for atrial fibrillation: a systematic review and meta-analysis.
Weiwei Sun, Ruiting Feng, Xiaohong Fu, Nan Zhang, Meng Sun, Min Guo, Jia Gao, Rui Wang
The First Clinical Medical College, Shanxi Medical University, Taiyuan, Shanxi, China. · Department of Cardiology, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China.
Key points
From the paper's conclusion- Systematic Review Registration https://www.crd.york.ac.uk/PROSPERO/view/CRD420251165071 , identifier (CRD420251165071).
Abstract
BACKGROUND: Pulsed field ablation (PFA) has emerged as a promising therapy for atrial fibrillation. While general anesthesia (GA) is the standard to ensure catheter stability, using conscious or deep sedation (CS/DS) to streamline workflows is gaining interest. However, whether CS/DS provides comparable safety and efficacy to GA remains controversial and has lacked systematic evaluation. OBJECTIVES: To compare the clinical efficacy and safety of PFA for atrial fibrillation under GA vs. CS/DS. METHODS: A literature search was conducted in PubMed, Cochrane Library, and Embase from inception to April 9, 2026. Studies were selected using predefined inclusion and exclusion criteria. The comparison of GA and CS/DS during PFA focused on the following clinical outcomes: procedural time, left atrial dwell time, fluoroscopy time, pulmonary vein isolation (PVI) success rate, and adverse event incidence. Heterogeneity was assessed with the I² statistic and Cochran's Q test; sensitivity analysis was performed if heterogeneity was high. Publication bias was evaluated using funnel plots and Egger's test. RESULTS: Ten studies involving 3,692 atrial fibrillation patients were included. Compared to GA, CS/DS significantly shortened overall procedural time (WMD: -7.73 min, random-effects; 95% CI: -14.17 to -1.29; P = 0.019). However, there were no significant differences between the groups in left atrial dwell time (WMD: -2.59 min, random-effects; 95% CI: -9.74 to 4.57), fluoroscopy time (WMD: -2.52 min, random-effects; 95% CI: -5.31 to 0.28), acute PVI success (RR: 1.00, fixed-effects; 95% CI: 0.98 to 1.03), or major adverse events (RR: 1.57, fixed-effects; 95% CI: 0.81 to 3.05). CS/DS showed a borderline trend toward fewer minor adverse events (RR: 0.61, fixed-effects; 95% CI: 0.37 to 1.01; P = 0.053). CONCLUSION: In PFA for AF, CS/DS was associated with reduced overall procedural time compared with GA, while maintaining comparable acute PVI success rates and safety profiles. However, large-scale randomized controlled trials are still needed to confirm these findings. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/PROSPERO/view/CRD420251165071, identifier (CRD420251165071).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrophysiology Team-Administered Conscious Sedation for Pulsed-Field Versus Radiofrequency Ablation in Atrial Fibrillation.Anesthesiology research and practice · 2026
- Characterization of sedation strategies in real-world use of pulsed field ablation Sub-analysis of the EU-PORIA registryEP Europace · 2025
- Sedation and anaesthesia in pulsed-field ablation for atrial fibrillation: mechanisms, procedural requirements, and real-world practice.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Sedation strategies for pulsed field ablation: a FARADISE registry sub-analysisEuropean Heart Journal · 2026
- Outcomes and patient satisfaction of deep sedation versus general anesthesia during dual-energy catheter ablation for paroxysmal atrial fibrillation: a randomized clinical trialEuropean Heart Journal · 2026
- Pulsed Field Ablation Using a Novel Biphasic Catheter vs Thermal Ablation for Paroxysmal Atrial FibrillationJournal of the American College of Cardiology · 2025