External validation of the D-PACE score for predicting late high-grade atrioventricular block after transcatheter aortic valve replacement in a Colombian cohort.
Juan David Zuluaga-Monroy, Hugo Oswaldo Alvarado Mora, Diana Fernanda Bohórquez González, Joshua Kock Sierra, Edgar Fernando Hurtado Ordoñez
Department of Interventional Cardiology, Fundación Abood Shaio, Bogotá, Colombia. · Department of Clinical Epidemiology, Universidad de La Sabana, Chía, Colombia.
Key points
From the paper's conclusion- Conclusions Applied as originally specified, the D-PACE score showed good discrimination for late high-grade AVB in this cohort (AUC 0.82; 95% CI 0.71–0.92).
Abstract
BACKGROUND: Transcatheter aortic valve replacement (TAVR) carries a clinically significant risk of late high-grade atrioventricular block (AVB), yet no validated tool exists to predict this complication in Latin-American populations. The D-PACE score was developed in European cohorts for this purpose. METHODS: In a retrospective cohort of 175 consecutive TAVR procedures at a Colombian center (2012-2025), 141 patients met inclusion criteria for D-PACE validation. The primary outcome was late high-grade AVB (≥Mobitz type II) occurring between 24 h and 30 days post-TAVR. Discrimination, logistic-regression calibration, and decision curve analysis were performed. RESULTS: Late AVB occurred in 31 patients (22.0%), with 80.6% of events within 72 h. The D-PACE score demonstrated good discrimination (AUC 0.82; 95% CI 0.71-0.92; sensitivity 77.4%, specificity 86.4% at a cutoff of 5.5 points; NPV 93.1%). Late AVB rates rose progressively across strata: 5.9% (low-risk, score 0-3), 8.8% (intermediate, 4-5), and 61.5% (high-risk, ≥6), with the high-risk group concentrating 77.4% of all events. Decision curve analysis confirmed net clinical benefit across threshold probabilities from 8% to 60%. All four low-risk events occurred among valve-in-valve patients assigned a score of 0 per the original algorithm; excluding this subgroup (N = 114), the AUC rose to 0.91 (95% CI 0.85-0.96) with zero low-risk events. In an exploratory analysis applying the full seven-variable scoring uniformly, including valve-in-valve cases, the AUC was 0.90 (95% CI 0.85-0.95; NPV 96.7%), and 0.91 (95% CI 0.78-1.00) within the valve-in-valve subgroup (N = 27, 4 events). CONCLUSIONS: Applied as originally specified, the D-PACE score showed good discrimination for late high-grade AVB in this cohort (AUC 0.82; 95% CI 0.71-0.92). The algorithm's automatic low-risk classification of valve-in-valve patients was not supported (14.8% AVB rate). Discrimination was higher both in the sensitivity analysis excluding valve-in-valve cases and in the exploratory analysis applying the seven-variable scoring uniformly, indicating that the scoring variables transfer well while the valve-in-valve exemption warrants reconsideration. These findings provide the first external validation of D-PACE in Latin America.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a risk stratification model for permanent pacemaker implantation after Transcatheter Aortic Valve Replacement (TAVR)European Heart Journal · 2026
- Deep Learning-Based Single-View Echocardiographic Analysis for Prediction of Left Ventricular Outflow Tract Gradient Elevation After Transcatheter Aortic Valve ReplacementmedRxiv · 2026
- A deep learning-based single-view echocardiographic analysis for prediction of left ventricular outflow tract obstruction after transcatheter aortic valve implantationEuropean Heart Journal · 2026
- Prognostic impact of new-onset atrial fibrillation and left bundle branch block after TAVR: a propensity-matched landmark analysisEuropean Heart Journal · 2026
- Door-to-Valve Time and Clinical Outcomes in Acute Decompensated Severe Aortic Stenosis: Systematic Review and Meta-AnalysismedRxiv · 2026
- Incidence and predictors of deaht and heart failure hospitalization on TAVI waiting list: a multicenter italian registryEuropean Heart Journal · 2026