Prevalence of nocturnal and isolated nocturnal hypertension in population-based studies: a systematic review and meta-analysis.
Víctor Juan Vera-Ponce, Jhosmer Ballena-Caicedo, Lupita Ana Maria Valladolid-Sandoval, Fiorella E Zuzunaga-Montoya
Facultad de Medicina (FAMED), Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas (UNTRM), Chachapoyas, Amazonas, Peru.
Key points
From the paper's conclusion- Systematic Review Registration https://www.crd.york.ac.uk/PROSPERO/view/CRD420251233166 , identifier PROSPERO CRD420251233166.
Abstract
BACKGROUND: Nocturnal hypertension (NH) and isolated nocturnal hypertension (INH) require nighttime blood pressure assessment, but published prevalence estimates differ in sampling, treatment eligibility, and ambulatory blood pressure monitoring (ABPM) protocols. OBJECTIVE: This study aimed to summarize NH and study-defined INH proportions in population/community samples. METHODS: Four databases were searched through 17 March 2026. Logit random-effects models used restricted maximum likelihood and modified Hartung-Knapp confidence intervals (CIs). Risk of bias was assessed using the nine-item Joanna Briggs Institute (JBI) 2017 checklist. Clinical/occupational and circadian-pattern reports were described individually rather than pooled. RESULTS: Nine NH estimates from four sources included 8,282 participants and 3,331 cases. Pooled prevalence was 42.5% (95% CI, 33.2%-52.3%; approximate 95% prediction interval, 17.2%-72.3%; I2 = 97.6%). Four INH estimates included 3,659 participants and 657 cases; the descriptive pooled proportion was 17.3% (95% CI, 10.4%-27.5%; prediction interval, 3.6%-54.0%; I2 = 91.5%). INH denominators differed by treatment eligibility; a sensitivity analysis using reported non-treated denominators yielded 19.6% (95% CI, 11.4%-31.6%). Certainty was judged very low. A sensitivity requiring both original nighttime recording-quality criteria could not be estimated from the published aggregate data. CONCLUSIONS: NH and INH were common in the population-based and community samples studied. These findings provide reference estimates for planning population-based studies and evaluating targeted detection strategies using ABPM. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/PROSPERO/view/CRD420251233166, identifier PROSPERO CRD420251233166.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Non-Dipping Blood Pressure and Routine Inflammatory Biomarkers: A Retrospective Cross-Sectional Diagnostic Accuracy StudyDiagnostics · 2026
- Are nocturnal home and ambulatory blood pressure measurements clinically interchangeable during high-risk pregnancy?Pregnancy hypertension · 2026
- Isolated nocturnal hypertension in type 2 diabetes: Impact of different ambulatory blood pressure thresholds on prevalence and reclassification.Diabetes & metabolic syndrome · 2026
- Phenotype-Dependent Effect of Bedtime Antihypertensive Dosing on Nocturnal Blood Pressure: A Meta-Analysis Guided by Non-Dipper Prevalence.Journal of clinical hypertension (Greenwich, Conn.) · 2026
- Persistent Hypertension After Asymptomatic Elevated In-Hospital Blood Pressure: The INDEBP StudymedRxiv · 2026
- The TyG-WHtR index as a novel predictor of nocturnal hypertension in metabolic syndrome.Frontiers in cardiovascular medicine · 2026