Frontiers in cardiovascular medicine

Pre- and intra-operative risk factors for re-operation after valve sparing aortic root replacement using the David technique. Results from two European centers.

Armin Darius Peivandi, Andreas Martens, Felix Fleißner, Ruslan Natanov, Morsi Arar, Florian Helms, Malakh Shrestha, Heike Krüger,

Department of Cardiac Surgery, Klinikum Oldenburg, Oldenburg, Germany. · Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany.

Observational · n=1,074

Key points

From the paper's conclusion
  • Bicuspid aortic valve, higher pre-operative AI, NYHA grade and male sex were independent risk factors for re-operation. Higher age and larger prosthesis sizes were protective factors. Further multi-center research is needed to validate and refine the prediction model.

Abstract

BACKGROUND: This study investigates pre- and intra-operative risk factors for re-operation after valve sparing aortic root replacement using the David technique to develop a risk model. METHODS: A retrospective cohort study of two European centers, comprising data from 07/1993 to 01/2025 was performed. Follow up time was 120 (IQR: 141) months. Primary outcome was aortic valve re-operation. Prediction model was developed using uni- and multivariable logistic regression analysis. A risk score was derived. Calibration in the large and slope were performed. Receiver operating characteristic (ROC) analysis allowed discrimination assessment. RESULTS: 1,074 patients were included. Male sex (OR: 1.98; 95% CI: 1.16-3.39, p = 0.012), age at operation (OR: 0.98; 95% CI: 0.97-0.996; p = 0.011), pre-operative AI grade (OR: 1.61; 95% CI: 1.21-2.14; p = 0.001), NYHA (OR: 1.29; 95% CI: 1.0043-1.67; p = 0.046), bicuspid aortic valve (OR: 2.03, 95% CI: 1.18-3.49; p = 0.011) and prosthesis size (OR: 0.76; 95% CI: 0.66-0.86; p < 0.001) remained independent predictors in multivariable analysis. The risk model showed moderate discrimination [AUC: 0.722 (95% CI: 0.677-0.766)] and good calibration in the original cohort [intercept: -0.00 (95% CI: -0.49-0.49); slope: 1.00 (95% CI: 0.75-1.26)]. CONCLUSION: Bicuspid aortic valve, higher pre-operative AI, NYHA grade and male sex were independent risk factors for re-operation. Higher age and larger prosthesis sizes were protective factors. Further multi-center research is needed to validate and refine the prediction model.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Pre- and intra-operative risk factors for re-operation after valve sparing aortic root replacement using the David technique. Results from two European centers — Science Skim