Transcatheter aortic valve replacement in failed transcatheter versus failed surgical bioprostheses: a systematic review with exploratory meta-analysis.
Mohammad Ghannam, Mustafa Abomohsen, Iyad Y Idries, Fayez Shamoon, Muhammad Ghallab, Fawzi Zghyer, Alena V González, Abdullah Ahmad,
Brookdale University Hospital and Medical Center, Brooklyn, NY, United States. · St. Joseph's University Medical Center, Paterson, NJ, United States.
Key points
From the paper's conclusion- Current comparative evidence between TAV-in-TAV and TAV-in-SAV remains limited and observational. No definitive mortality difference was identified, but clinically meaningful benefit or harm cannot be excluded. TAV-in-TAV shows a consistent early haemodynamic signal with lower gradients, while the possible increase in pacemaker implantation remains exploratory. These findings should be considered hypothesis-generating and require confirmation in larger prospective studies with longer follow-up.
Abstract
BACKGROUND: With the expanding use of transcatheter aortic valve replacement (TAVR) in younger patients, the need for reintervention on failed bioprostheses is rising. Comparative evidence between redo TAVR for failed transcatheter valves (TAV-in-TAV) and TAVR for failed surgical valves (TAV-in-SAV) is limited. OBJECTIVE: To systematically review and meta-analyse the clinical, haemodynamic, and safety outcomes of TAV-in-TAV versus TAV-in-SAV. METHODS: PubMed, Scopus, Web of Science, Cochrane CENTRAL, and Embase were searched from inception to April 2026. Studies directly comparing TAV-in-TAV with TAV-in-SAV and reporting original data with ≥10 patients per group were included. Risk of bias was assessed using ROBINS-I and the Newcastle-Ottawa Scale. Random-effects meta-analyses were performed for 30-day mortality, 1-year mortality, mean transvalvular gradient at 30 days, and new permanent pacemaker (PPM) implantation. RESULTS: Four observational studies, including 705 patients in the extracted comparative cohorts, met the inclusion criteria. Two full-text studies contributed to the primary quantitative analyses. TAV-in-TAV was not associated with a statistically significant difference in 30-day mortality compared with TAV-in-SAV (OR 0.71, 95% CI 0.25-2.00), nor in 1-year mortality (OR 1.02, 95% CI 0.47-2.18). TAV-in-TAV was associated with lower mean transvalvular gradients at 30 days (MD -2.71 mmHg, 95% CI -4.07 to -1.34). A non-significant trend toward higher new permanent pacemaker implantation was observed after TAV-in-TAV (OR 1.85, 95% CI 0.94-3.65). CONCLUSION: Current comparative evidence between TAV-in-TAV and TAV-in-SAV remains limited and observational. No definitive mortality difference was identified, but clinically meaningful benefit or harm cannot be excluded. TAV-in-TAV shows a consistent early haemodynamic signal with lower gradients, while the possible increase in pacemaker implantation remains exploratory. These findings should be considered hypothesis-generating and require confirmation in larger prospective studies with longer follow-up. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/PROSPERO/view/CRD420261369410, PROSPERO CRD420261369410.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Redo-Transcatheter Aortic Valve Implantation Versus Surgical Explantation in Patients With Previous Transcatheter Aortic Valve Implantation: A Systematic Review and Meta-Analysis.Journal of the American Heart Association · 2026
- Three-year outcomes of balloon-expandable valve-in-valve aortic valve implantation for failed transcatheter versus surgical valves.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2026
- Impact of Initial Valve Type on Reintervention for TAVR Failure: From the EXPLANTORREDO-TAVR International Registry.Circulation. Cardiovascular interventions · 2026
- Redo-Transcatheter Aortic Valve Replacement With Self-Expanding Valves: A U.S. Registry Analysis.JACC. Cardiovascular interventions · 2026
- Long-Term Reintervention, Clinical Valve Failure, and Outcomes After Transcatheter Aortic Valve Replacement: A National Real-World StudymedRxiv · 2026
- Transcatheter aortic valve-in-valve implantation for failed surgical aortic bioprostheses using the Navitor platform: early outcomes in a consecutive single-center cohort.Cardiology journal · 2026