Zero-fluoroscopy catheter ablation for arrhythmias in pregnancy: validation of a standardized approach with 5-year follow-up.
Sebastian Stec, Marek Bronisz, Joanna Kornaszewska, Katarzyna Styczkiewicz, Marcin Nosal, Alicja Hajduk-Hejnar, Anna Kustroń, Szymon Stec,
Department of Cardiac Surgery and Transplantology, National Medical Institute of the Ministry of Interior and Administration and Institute for Cardiovascular Science, CardioNeuroLab, CardioMedicum, Kraków, Poland. · Pathology Department, University of Opole, Opole, Poland.
Key points
From the paper's conclusion- The implementation of a pregnancy heart team and a standardized fluoroless protocol for CA in routine electrophysiological practice enables safe and effective ablation of maternal supraventricular tachycardia and idiopathic ventricular arrhythmias during pregnancy.
Abstract
BACKGROUND: Increasing experience with zero- (ZF) or near-zero fluoroscopy catheter ablation (CA) supports the implementation of an early fluoroless approach for recurrent, symptomatic arrhythmias during pregnancy. AIM: This study evaluated the feasibility, efficacy, and safety of CA using a standardized ZF approach during pregnancy. METHODS: Data were derived from a large, prospective multicenter registry (ELEKTRO-RARE-A-CAREgistry). Between 2012 and 2019, more than 2,655 CA procedures were performed in women using an intention-to-treat ZF approach. The procedures were performed using (1) femoral access, (2) a double-catheter technique without intracardiac echocardiography, (3) an electroanatomic mapping system for mapping and navigation, and (4) conscious light sedation. A shared decision-making approach was applied, including consultation with a pregnancy heart team. RESULTS: The study group consisted of 18 consecutive pregnant women without structural heart disease (mean age: 30.6 ± 4.7 years; range: 20-38 years). The mean gestational age at the time of CA was 20.2 ± 9.5 weeks (range: 7-37 weeks), representing <0.01% of all female patients referred for CA. During 18 index procedures, a total of 21 arrhythmogenic substrates were ablated. The major indications for CA during pregnancy were atrioventricular nodal reentrant tachycardia (n = 10), orthodromic atrioventricular reentrant tachycardia (n = 2), focal idiopathic ventricular arrhythmia (n = 5), atrial tachycardia (n = 2), and atrial fibrillation (AF; n = 1). In the patient with AF, general anesthesia and transesophageal echocardiography were used to guide ZF transseptal puncture and isolation of the right pulmonary veins, where focal AF triggers were identified. All the procedures were successfully completed without fluoroscopy and without serious maternal or fetal complications. The mean procedure and ablation application times were 51.5 ± 6.8 min and 394 ± 338 s, respectively. In one patient, CA of a second premature ventricular contraction focus was postponed until after delivery. After a 5-year follow-up, no adverse effects related to CA performed during pregnancy were observed in the children, and CA was effective in 80% of the women. CONCLUSIONS: The implementation of a pregnancy heart team and a standardized fluoroless protocol for CA in routine electrophysiological practice enables safe and effective ablation of maternal supraventricular tachycardia and idiopathic ventricular arrhythmias during pregnancy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Zero-fluoroscopy, intracardiac echocardiography-only patent foramen ovale closure in early pregnancy: a case report.European heart journal. Case reports · 2026
- Fluoroless Workflow for Pulsed Field Ablation of Atrial Fibrillation Using the Sphere-9 and VARIPULSE Catheters.Journal of clinical medicine · 2026
- Catheter ablation of atrial fibrillation using the pulsed-field energy; a prospective randomized comparison of the CENTAURI PEF system and the FARAPULSE SystemEuropean Heart Journal · 2026
- Intracardiac echocardiography guided zero-fluoroscopy workflow versus conventional fluoroscopy-guided workflow in atrial fibrillation ablation: efficiency, safety, and operator experience.Frontiers in medicine · 2026
- From trial to practice: early multicenter real-world experience with the circular pulsed field ablation catheterJournal of Interventional Cardiac Electrophysiology · 2026
- Contemporary Outcomes of Catheter Ablation of Long-Standing Persistent Atrial Fibrillation.Journal of cardiovascular electrophysiology · 2026