Comparative analysis of two radial hemostasis strategies following percutaneous coronary intervention: a prospective, single-center, real-world cohort study.
Pablo Juan-Salvadores, Samuel Pintos-Rodríguez, Cristina Herrera Álvarez, Julio Echarte Morales, Silvia González Suárez, María Luisa Núñez Seoane, Paula Pérez Rey, Rebeca Míguez Baquero,
Cardiovascular Research Unit, Cardiology Department, Hospital Álvaro Cunqueiro, University Hospital of Vigo, Vigo, Spain. · Interventional Cardiology Unit, Department of Cardiology, Hospital Álvaro Cunqueiro, Área Sanitaria de Vigo, Vigo, Spain.
Key points
From the paper's conclusion- Compared with TR-Closure band™, VIRUNDA® reduced bleeding, pain and paresis, and shortened compression time, without a significant increase in immediate radial occlusion. These findings support its use as a safe and efficient hemostatic alternative in routine practice.
Abstract
BACKGROUND: Radial access is currently the approach of choice for coronary interventional procedures. However, puncture and hemostasis are not exempt from access site complications. This study evaluated the efficacy and safety of two radial hemostasis devices used after percutaneous coronary intervention (PCI) in routine clinical practice. METHODS: A prospective, single-center, real-world cohort study was carried out. Consecutive patients undergoing coronary angiography or PCI via radial access between February 2023 and October 2024 were included. Depending on the hemostasis technique used, the patients were assigned to TR-Closure band™ or a dedicated pad (VIRUNDA®). Access site complications were assessed at the time of device removal. RESULTS: A total of 597 patients were included (TR-Closure band™ n = 282; VIRUNDA® n = 315). The median age was 71 years (63-78); 409 (68.5%) were male. Compression time was shorter with VIRUNDA® [median 113 [90-133] vs. 148 [125-180] minutes; p < 0.001]. VIRUNDA® was associated with lower bleeding rates [Bleeding Academic Research Consortium (BARC) score 1: 9.8% vs. 58.2%], less pain during compression (10.5% vs. 19.9%) and after compression (5.4% vs. 13.8%), and less paresis (2.5% vs. 8.5%) (all p ≤ 0.001). Hematoma was more frequent with TR-Closure band™ (27.7% vs. 19.4%; p = 0.009). The immediate radial artery occlusion rates were similar (9.2% vs. 4.6%; p = 0.143). The multivariate analysis identified the use of VIRUNDA® as an independent protective factor (RR 0.171; 95%CI 0.119-0.245; p < 0.001). CONCLUSIONS: Compared with TR-Closure band™, VIRUNDA® reduced bleeding, pain and paresis, and shortened compression time, without a significant increase in immediate radial occlusion. These findings support its use as a safe and efficient hemostatic alternative in routine practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A novel distal radial artery compression device versus elastic bandage compression after coronary angiography or percutaneous coronary intervention via distal transradial access: a prospective randomized controlled trial.BMC cardiovascular disorders · 2026
- Safe and Fast Radial Artery Hemostasis Using Synergistic Strategies: SAFE and FAST Trial.The American journal of cardiology · 2026
- A randomised controlled trial comparing a 100% chitosan haemostatic dressing and a manual compression device following transradial coronary intervention.AsiaIntervention · 2026
- Pressure-guided pneumatic radial compression and radial artery occlusion after transradial coronary procedures: a retrospective historical cohort study.Scandinavian cardiovascular journal : SCJ · 2026
- Distal radial access dramatically reduces hemostasis time and bleeding in coronary interventions: a meta-analysis of 7 randomized trialsEuropean Heart Journal · 2026
- Transradial Versus Transfemoral Access for Percutaneous Coronary Intervention: Procedural Efficiency, Radiation Exposure and In-Hospital Outcomes in a Real-World Single-Center Cohort.Journal of clinical medicine · 2026