Biomarker response to balloon-in-basket pulsed field ablation: does posterior wall isolation matter?
Sascha Hatahet, Sorin Popescu, Charlotte Eitel, Suzanne de Waha, Tanja Zeller, Karl-Heinz Kuck, Jan‐Per Wenzel, Roland Richard Tilz
University Hospital Schleswig-Holstein
Key points
From the paper's conclusion- Background A novel balloon-in-basket pulsed field ablation (BiB-PFA) catheter enables efficient pulmonary vein isolation (PVI) and allows posterior wall isolation (PWI) within the same procedure.
Abstract
Background A novel balloon-in-basket pulsed field ablation (BiB-PFA) catheter enables efficient pulmonary vein isolation (PVI) and allows posterior wall isolation (PWI) within the same procedure. The incremental biological effect of PWI compared to PVI alone remains uncertain, particularly regarding inflammation, myocardial injury, and hemolysis. Methods In this prospective, single-center study, consecutive patients with atrial fibrillation underwent first-time BiB-PFA, either PVI only or PVI plus PWI. Venous blood samples were collected before and one day after ablation. Biomarkers included leukocytes, platelets, hemoglobin, C-reactive protein (CRP), haptoglobin, bilirubin, lactate dehydrogenase (LDH), creatinine, estimated glomerular filtration rate (GFR), myoglobin, creatine kinase (CK), and troponin T. Results A total of 60 patients were enrolled (PVI only n = 30, PVI + PWI n = 30). Baseline characteristics were comparable. PVI + PWI required more applications (19 vs. 16; p < 0.001) but had similar procedure time. Both groups showed significant increases in inflammatory (CRP, leukocytes), myocardial (troponin T, CK, LDH, myoglobin), and hemolysis markers (bilirubin, LDH, haptoglobin changes; all p < 0.001). However, the magnitude of biomarker release did not differ between PVI only and PVI + PWI: Δ troponin T (1,154 vs. 1,029 ng/L, p = 0.694), Δ CK (217 vs. 197 U/L, p = 0.652), Δ CRP (2.7 vs. 3.4 mg/L, p = 0.475), Δ bilirubin (2.4 vs. 2.8 µmol/L, p = 0.842), Δ creatinine (3.3 vs. 9.0 µmol/L, p = 0.085). Conclusion BiB-PFA PVI provokes systemic responses involving inflammation, myocardial injury, and hemolysis. Adjunctive PWI increases application number but does not further increase biomarker release, supporting the biological safety of PWI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inflammatory and Myocardial Biomarker Response Following Pulmonary Vein Isolation: Cryoballoon Versus Balloon‐in‐Basket Pulsed Field AblationJournal of Cardiovascular Electrophysiology · 2025
- Real-World Experience With the Balloon-in-Basket Pulsed Field Ablation System for Pulmonary Vein Isolation and Ablation of Extra-Pulmonary Vein Sites.Journal of cardiovascular electrophysiology · 2026
- Physiological Tissue Response to Pulsed-Field Ablation for Atrial Fibrillation: Insights from Biomarker Kinetics.Physiological research · 2026
- Delayed myocardial injury and reduced inflammation after pulsed-field vs. cryoballoon vs. radiofrequency ablation for atrial fibrillationEuropean Heart Journal · 2026
- Catheter Design Matters: Hemolysis and Renal Function after Pulsed Field Ablation with Balloon-in-Basket vs. Pentaspline SystemsJournal of Interventional Cardiac Electrophysiology · 2025
- Pulmonary vein isolation using a novel balloon-in-basket pulsed field ablation system: The Lübeck how-to protocolHeart Rhythm O2 · 2026