Frontiers in Computer Science

An integrated AI-based software architecture for load forecasting, controlled anomaly detection, and predictive energy management

Karlygash Alibekkyzy, Gulnur Massabayeva, Michał Majka, Madina Bazarova, Daniyar Kaliyev, Talshyn Keribayeva, Saule Belginova, Alina Bugubayeva

Key points

From the paper's conclusion
  • The results demonstrate that the joint integration of forecasting, anomaly detection, and predictive control provides a computationally coherent framework for supporting energy-management efficiency, operational reliability, and data-driven decision-making in intelligent energy systems.

Abstract

The increasing deployment of smart meters and Internet of Things technologies has created a demand for intelligent computational systems capable of jointly forecasting electricity consumption, detecting abnormal behavior, and optimizing load management. This study proposes an integrated artificial intelligence-based framework for automated energy metering and consumption management in smart-grid environments. The framework combines a Long Short-Term Memory network for short-term load forecasting, an autoencoder-based model for anomaly detection, and Model Predictive Control for demand-side optimization. The system architecture includes data acquisition, communication, preprocessing, predictive analytics, anomaly monitoring, and decision-support layers. The primary empirical evaluation used 4,380 measured hourly observations (approximately 6 months) from a single administrative building. A separately flagged synthetic temporal extension was retained only as an auxiliary dataset and was excluded from all primary performance metrics. Across five independent model initializations, the final LSTM achieved a MAPE of 3.423 ± 0.555%, an RMSE of 0.336 ± 0.048 kW, and an R 2 of 0.973 ± 0.007 on the 633-sequence independent measured test subset. The synthetic extension was maintained as a separately identified auxiliary component and was excluded from all primary training, validation, and independent test metrics. Using a validation-selected reconstruction-error threshold, the autoencoder detected 12 of 30 controlled anomalies in the independent test subset, yielding 100.00% precision, 40.00% recall, and an F1-score of 57.14%. Under the same controlled protocol, One-Class SVM achieved higher recall (53.33%) and F1-score (69.57%), indicating that the autoencoder should be interpreted as an architectural component rather than as the best-performing anomaly detector for the present dataset. A historical proof-of-concept MPC simulation, retained for architectural illustration, reported a 15% reduction in simulated peak demand and a 12% reduction in estimated electricity cost; these values are not interpreted as measured outcomes from the administrative-building experiment. Controlled anomaly injection was used to establish reproducible validation and test labels for the anomaly-detection component. The results demonstrate that the joint integration of forecasting, anomaly detection, and predictive control provides a computationally coherent framework for supporting energy-management efficiency, operational reliability, and data-driven decision-making in intelligent energy systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

An integrated AI-based software architecture for load forecasting, controlled anomaly detection, and predictive energy management — Science Skim