Frontiers in cellular and infection microbiology

Highly sensitive and specific detection of aminoglycoside resistance methylase gene armA by multiple cross displacement amplification-CRISPR/Cas12a technique.

Lin Gong, Juan Wang, Yuandong Zhang, Huiqiong Xu, Xiaoli Liu, Xiaomin Chen, Meiling Li, Yao Li,

State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Health Effects of Environmental Pollution, Ministry of Ecology and Environment, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China. · Department of Disinfection and Pest Control, Wuhan Center for Disease Control & Prevention, Wuhan, Hubei, China.

Key points

From the paper's conclusion
  • Methods A multiple cross displacement amplification (MCDA) combined with CRISPR/Cas12a system assay was established to identify armA gene with rapidity, specificity, and sensitivity.

Abstract

INTRODUCTION: The 16S rRNA methylase armA serves as a key molecular determinant conferring high-level resistance to aminoglycoside antibiotics in bacterial pathogens. Development of a rapid and reliable armA gene detection assay will improve surveillance of enzyme-producing strains and support drug resistance control in diverse ecological settings. METHODS: A multiple cross displacement amplification (MCDA) combined with CRISPR/Cas12a system assay was established to identify armA gene with rapidity, specificity, and sensitivity. RESULTS: The entire experimental process, including genomic DNA extraction (15 minutes), MCDA reaction (40 minutes), CRISPR/Cas12a-mediated cleavage (5 minutes), and fluorescence detection (10 minutes), can be completed within 70 minutes. In terms of analytical specificity, the assay yielded positive results for all armA-positive isolates and negative results for all non-armA samples. The sensitivity of the MCDA-CRISPR/Cas12a assay reached a detection limit as low as 10 copies/mL of armA-positive plasmid DNA. In 129 cultured clinical isolates validated by whole-genome sequencing, the assay achieved 100% concordance for armA detection. DISCUSSION: The technique established in this study provides a rapid and accurate diagnostic approach for laboratory-based surveillance of armA in clinical and livestock settings, with future potential for point-of-care adaptation following further simplification and validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers