Sensitive and rapid detection of Candida tropicalis using closed dumbbell-mediated isothermal amplification.
Yangbo Fu, Jing Shen, Haizhong Jiang, Yanli Zhang, Xuhan Chen, Rui Mao
The First Affiliated Hospital of Ningbo University, Ningbo, Zhejiang, China. · Ningbo No. 2 Hospital, Wenzhou Medical University, Ningbo, Zhejiang, China.
Key points
From the paper's conclusion- The C. tropicalis CDA assay demonstrated perfect diagnostic performance with apparent 100% sensitivity (95%CI = 97.0%-100%), specificity (95%CI = 98.5%-100%), and accuracy (95%CI = 99.0%-100%) in a primary evaluation using 364 batches of diverse DNA samples, with a limit of detection of 5.6 × 10-6 ng/μl (approximately 10 copies/μl), which is not significantly different from that of real-time quantitative PCR (qPCR), indicating comparable analytical sensitivity.
Abstract
INTRODUCTION: Candida tropicalis is responsible for a substantial proportion of invasive candidiasis cases and is recognized as the second most prevalent causative agent, only behind Candida albicans. A documented rise in invasive systemic infections and sepsis due to C. tropicalis has contributed to the increased mortality among vulnerable patient populations, highlighting the critical need for heightened clinical vigilance. Early detection of C. tropicalis is essential for guiding appropriate antifungal therapy and is associated with improved clinical outcomes. METHODS: To address the need for rapid and reliable detection of C. tropicalis, this research aimed to develop a novel closed dumbbell-mediated isothermal amplification (CDA) assay characterized by high speed, specificity, and efficiency. A set of specific CDA primers targeting the conserved ITS2 gene of C. tropicalis was successfully designed, selected, and validated, resulting in a simple and efficient detection method. The C. tropicalis CDA assay for in vitro diagnostic applications demonstrated robust performance, with its sensitivity, robustness, stability, and specificity systematically evaluated using 364 batches of diverse DNA samples. RESULTS: The C. tropicalis CDA assay demonstrated perfect diagnostic performance with apparent 100% sensitivity (95%CI = 97.0%-100%), specificity (95%CI = 98.5%-100%), and accuracy (95%CI = 99.0%-100%) in a primary evaluation using 364 batches of diverse DNA samples, with a limit of detection of 5.6 × 10-6 ng/μl (approximately 10 copies/μl), which is not significantly different from that of real-time quantitative PCR (qPCR), indicating comparable analytical sensitivity. DISCUSSION: Validated in both real-time fluorescence and endpoint visual formats, the C. tropicalis CDA assay demonstrated high specificity, sensitivity, and accuracy, along with robust stability and reproducibility, supporting its future application potential.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid and ultrasensitive detection of Candida tropicalis using multiple cross-displacement amplification combined with CRISPR/Cas12a.Frontiers in cellular and infection microbiology · 2026
- Rapid antifungal phenotypic detection of Candida tropicalis based on laser-scattering technology combined with machine learning.Frontiers in cellular and infection microbiology · 2026
- Biofilm formation directly correlates with cell viability in Candida tropicalis on polypropyleneApplied Microbiology and Biotechnology · 2026
- Candidatropicalis: An Emerging Opportunistic Pathogen at the Interface of Virulence, Antifungal Resistance, and Host Immune Interactions.Microorganisms · 2026
- Persistent Non-albicans Predominance, High Mortality, and Azole-Non-Susceptible Candida tropicalis: A 15-Year Pediatric Invasive Candidiasis Cohort in Southern Thailand.Journal of fungi (Basel, Switzerland) · 2026
- Regional expansion and adaptive evolution of multidrug-resistant Candida tropicalis in China: a retrospective, multicentre, genomic study.The Lancet. Microbe · 2026