Frontiers in chemistry

A novel type V natural deep eutectic solvent with built-in pH-regulation for magnetic dispersive liquid-liquid microextraction of central nervous system drugs in plasma samples.

Wen-Chao Han, Yu-Ling Yang, Xiao-Bei Yang, Han-Juan Zhang, Yong-Yan Chen, Xi-Rui Pei, Dong-Dong Yuan, Di Chen

Department of Pharmacy, The Seventh People's Hospital of Zhengzhou, Zhengzhou, China. · Clinical Trial Institution for Drugs of Pharmacy Department, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou, China.

Key points

From the paper's conclusion
  • Introduction This study proposes an alkaline natural deep eutectic solvent (ANADES)-based magnetic dispersive liquid-liquid microextraction (ANADES-M-DLLME) method for the convenient, green, and efficient extraction of CNS drugs from plasma.

Abstract

INTRODUCTION: This study proposes an alkaline natural deep eutectic solvent (ANADES)-based magnetic dispersive liquid-liquid microextraction (ANADES-M-DLLME) method for the convenient, green, and efficient extraction of CNS drugs from plasma. METHODS: A novel, non-toxic type V ANADES, serving as the extractant, not only allows for polarity customization, but also directly adjusts the solution's pH to alkaline conditions due to its built-in pH regulation, significantly improving the extraction efficiency of CNS drugs. Moreover, the elimination of the external pH adjustment, combined with magnetic particle-assisted retrieval of the extractant, substantially streamlines the sample preparation process. RESULTS: Under the optimal extraction conditions, the developed method, coupled with GC-MS/MS detection, was successfully applied for the extraction and quantification of CNS drugs in human plasma samples. The validated method exhibited good linearity (R 2 > 0.990), with high accuracy (spiked recoveries 95.1%-114.9%) and precision (RSDs < 13.3%). Low limits of detection (0.61-3.36 ng/mL) and quantification (2.05-9.89 ng/mL), satisfactory extraction recoveries (85.01%-99.89%), and enrichment factors (6.65-8.79) were achieved for the seven target analytes. The analysis of the proposed method using three green analytical chemistry metrics further substantiated the method's greenness. DISCUSSION: Compared with reported DLLME techniques, the established ANADES-M-DLLME method was green, rapid, convenient, and cost-effective, offering a promising solution for widespread clinical and bioanalytical applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers