Flow measurement in high-temperature liquid metals and molten salts: principles, recent advances, and deployment challenges.
Geon Her, Yeongo Oh, Hyungmo Kim, Seonghyeon Kim
Department of Electrical Engineering, Gyeongsang National University, Jinju, Republic of Korea. · Bumsung Co., Ltd., Changwon, Republic of Korea.
Key points
From the paper's conclusion- Future high-temperature flow instrumentation will therefore require not only thermally robust sensors but also measurement systems that incorporate condition diagnostics, reduced calibration dependence, and cross-validation between independent physical principles.
Abstract
Next-generation energy systems-including sodium- and lead-cooled fast reactors, molten salt reactors, concentrating solar power, and fusion breeding blankets-rely on high-temperature liquid metals and molten salts operating at approximately 400 °C-700 °C, conditions under which conventional flow instrumentation becomes increasingly constrained. This Mini Review examines electromagnetic, ultrasonic, optical, differential-pressure, vortex, Coriolis, and thermal approaches to flow measurement, with an emphasis on the temperature-sensitive physical properties and sensor-fluid interfaces that govern measurement validity and practical deployment. Differences of several orders of magnitude in electrical conductivity between liquid metals and molten salts favor electromagnetic techniques in liquid metals, particularly sodium, while reducing the signal margin of conductivity-dependent inductive and Lorentz-force approaches in molten salts. Ultrasonic techniques are independent of electrical conductivity and have been demonstrated in high-temperature fluoride-salt loops, although acoustic coupling, thermal-interface stability, and long-term qualification remain important limitations. Across all principles, the central challenge is maintaining measurement validity in the presence of thermal drift, corrosion, changes in wetting, material degradation, and limited opportunities for recalibration. Future high-temperature flow instrumentation will therefore require not only thermally robust sensors but also measurement systems that incorporate condition diagnostics, reduced calibration dependence, and cross-validation between independent physical principles.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Study on the influence of different medium on the internal flow and dynamic characteristics of maglev molten salt pumpJournal of Physics: Conference Series · 2026
- Impact of helium cooling channels and flow channel inserts on magnetohydrodynamic mixed convection in a liquid metal blanket.Nuclear Fusion · 2026
- Impact of through-flow and swirling magnetohydrodynamic flows of liquid metal in a cylindrical channel on the transport of temperature non-uniformitiesPhysics of Fluids · 2026
- Multiphysics modelling of molten salt blankets for ARC-class fusion reactorsNuclear Fusion · 2026
- Numerical Investigation on the Thermal-Hydraulic Performance of Molten Salt in Internal Helically Finned TubesEnergies · 2026
- Wettability of molten salts on structural materials: implications for drain, flush, and freeze-valve operations in molten salt reactorsFrontiers in Physics · 2026