Establishing and validating a predictive model for long-term control outcomes following orthokeratology lenses wear: a five-year cohort study
Zixun Wang, Xiaoling Zhang, Xiaoxue Hu, Hui Miao, Shujun Zhang, Feng Chang, Ruihua Wei, Zheng Guo
Tianjin Medical University Eye Hospital · Han Dan City Eye Hospital - The Third Hospital of Handan
Key points
From the paper's conclusion- Conclusion: A robust and interpretable predictive model was developed to estimate 5-year Ortho-K lens control efficacy using Δ1, Δ3, and flat E.
Abstract
Purpose: To develop and interpret a clinical prediction model for identifying children at risk of poor 5-year axial length (AL) control following orthokeratology (Ortho-K) lens wear, integrating traditional regression modeling with explainable machine learning. Methods: A total of 504 children with baseline myopia were included. The 5-year AL control outcome was defined as an AL increase of <1.0 mm (effective control, EC) or ≥1.0 mm (ineffective control, IC). Feature selection was performed using least absolute shrinkage and selection operator (LASSO), Boruta, and multivariable logistic regression. Machine learning (ML) model performance was evaluated across multiple algorithms, including logistic regression (LR), random forest (RF), support vector machine (SVM), artificial neural network (ANN), decision tree, light gradient boosting machine (lightGBM), and XGBoost. The best-performing model was visualized as a nomogram, dynamically deployed as a web-based risk calculator, and further interpreted using SHapley Additive exPlanations (SHAP) analysis. Results: Feature selection consistently identified a change in AL over the 3 years (Δ1, Δ2, Δ3), and flat E as the most stable predictors of 5-year AL control. Among all models, logistic regression achieved the best overall performance (F1 = 0.897, AUC = 0.969), while XGBoost showed the highest F1-score among ML methods. Enhancing clinical applicability and further simplifying the included parameters, the results Δ1, Δ3, and flat E still demonstrate strong predictive performance (F1 = 0.714, AUC = 0.949). The nomogram demonstrated good calibration and discrimination, with decision curve analysis confirming its clinical utility. SHAP interpretation revealed that Δ3 and Δ1 had the greatest influence on risk prediction, with a notable inflection point around 0.05 mm, beyond which the predicted risk of poor control increased sharply. Conclusion: A robust and interpretable predictive model was developed to estimate 5-year Ortho-K lens control efficacy using Δ1, Δ3, and flat E. The integrated SHAP analysis provided mechanistic insight and highlighted the clinical threshold (Δ3 = 0.05 mm) as a potential early warning indicator for suboptimal myopia control. The dynamic online nomogram enables individualized risk estimation and supports precision-guided intervention in pediatric myopia management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Establishing a prediction model for the therapeutic outcomes of short-term and long-term orthokeratology treatment: using baseline data and changes in AL as dynamic variablesBMC Medical Informatics and Decision Making · 2026
- Development and external validation of a prediction model for suboptimal orthokeratology control in adolescents.International journal of ophthalmology · 2026
- Early Axial Length Response Predicts Long-Term Myopia Control in Children Undergoing Orthokeratology.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Multicenter Validation of Machine Learning Models for Predicting Myopia Progression Across School‐Based Screening and Optical Intervention Settings in Chinese Children and AdolescentsAdvanced Intelligent Discovery · 2026
- Axial length changes and baseline predictors over five years in children treated with orthokeratology lenses: a retrospective cohort study.Frontiers in bioengineering and biotechnology · 2026
- Clinical outcomes and baseline factors associated with one-year axial elongation during orthokeratology wear in children: a retrospective study.BMC ophthalmology · 2026