Fractional seismic simulation and synthetic inverse identification of nonlinear building models: discrete energy balance, convergence, and equivalent-damping calibration
Alvaro H. Salas, Carlos D. Acosta M, Elizabeth Solórzano
Key points
From the paper's conclusion- We develop a revised nonlinear seismic-response framework for single- and multi-degree-of-freedom building models with Caputo damping.
Abstract
Fractional damping provides a compact representation of hereditary, frequency-dependent dissipation, but numerical and inverse conclusions can be misleading if the discrete energy behavior, damping calibration, and synthetic nature of the identification experiment are not made explicit. We develop a revised nonlinear seismic-response framework for single- and multi-degree-of-freedom building models with Caputo damping. The nonlinear restoring law is deliberately restricted to monotone cubic hardening; it is a mathematical benchmark and does not represent pinching, stiffness/strength degradation, or residual drift. The continuous system is locally well posed, globally continuable under a coercive potential, and dissipative in accumulated hereditary work. For time integration, a midpoint L1 product integration formula is coupled with average-acceleration Newmark kinematics and a discrete gradient of the nonlinear potential. The resulting fully implicit method has a uniquely solvable nonlinear step and satisfies a cumulative discrete energy balance; in an unforced free-vibration test, the relative balance defect is below 3 × 1 0 − 15 . For smooth solutions, a detailed consistency–stability argument yields a global O ( Δ t 2 − α ) displacement/velocity estimate under stated regularity and coercivity assumptions. A weakly singular manufactured solution demonstrates the expected loss of uniform-grid accuracy and the strong recovery obtained with a deliberately graded mesh. For the three-story benchmark, fractional damping matrices are no longer held fixed while changing α ; instead, every fractional model is calibrated to 4% equivalent damping in the first and third modes, matching the Rayleigh comparator on the same physical basis. Under this calibration, the previously large monotone demand reduction largely disappears: across 12 independent nonstationary synthetic motions, the mean roof displacement varies only from 4.285 cm to 4.355 cm among the fractional and viscous models, and paired 95% confidence intervals contain zero. Finally, synthetic inverse identification is evaluated on 600 parameter pairs using five-fold cross-validation, regression baselines, repeated 1–10% noise tests, structural-parameter perturbations, and an unseen-excitation stress test. Clean within-family parameter estimation remains accurate, but model mismatch and unseen excitation substantially degrade the estimates. The study therefore supports a reproducible methodological framework and numerical identifiability within a controlled model class, not validated real-building parameter recovery or universal seismic performance improvement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fast Spectral Simulation of One-Dimensional Nonlinear Fractional Waves in Attenuating MediaComputation · 2026
- Stability Analysis and Synchronization of Distributed-Order Fractional Nonlinear Dynamical Systems with Time DelayFractal and Fractional · 2026
- Stability for a wave equation with fractional structural damping subjected to an internal distributed delayGeorgian Mathematical Journal · 2026
- Space-time fractional modeling of memory and non-local effects in non-linear shallow water hydrodynamicsNonlinear Engineering · 2026
- Stability for Abstract Coupled Second-Order Evolution Equations with One Fractional Infinite MemorySymmetry · 2026
- Error-Balanced Adaptive B-Spline Galerkin Methods with Fast Memory for Time-Fractional Porous Medium EquationsMathematics · 2026