GaitScreen: a ground reaction force-based framework for prescreening gait abnormalities in orthopaedic populations.
Qingyao Bian, Qing Zhang, Yang Li, Ziyun Ding
School of Engineering, University of Birmingham, Birmingham, United Kingdom. · Gait and Motion Analysis Center, Yueyang Hospital of Integrative Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, China.
Key points
From the paper's conclusion- Under a subject-exclusive evaluation protocol, GaitScreen achieved consistent trial-level performance across ten matched runs, with an accuracy of 0.8766 ± 0.0025 , a macro-F1 score of 0.8757 ± 0.0024 , and an AUROC of 0.9425 ± 0.0015 .
Abstract
Ground reaction force (GRF) trajectories capture kinetic alterations in stance-phase loading, propulsion, and mediolateral control. This study presents GaitScreen, a GRF-based framework for post-acquisition prioritisation of already recorded healthy-control and pathological-gait trials. GaitScreen converts vertical, anterior-posterior, and mediolateral stance-phase GRF trajectories into a review-prioritisation score and a threshold-dependent review flag. The framework combines a multiscale temporal backbone, a convolutional neural network component, and a logistic regression component to integrate multiscale force patterns, learned convolutional representations, and raw-waveform linear information. It was evaluated using the GaitRec dataset, comprising healthy controls and individuals with lower-limb orthopaedic conditions. Under a subject-exclusive evaluation protocol, GaitScreen achieved consistent trial-level performance across ten matched runs, with an accuracy of 0.8766 ± 0.0025 , a macro-F1 score of 0.8757 ± 0.0024 , and an AUROC of 0.9425 ± 0.0015 . A high-sensitivity operating mode reduced the false-negative rate from 0.1736 to 0.1073, with an increase in false-positive review flags. The full hybrid model had a serialized size of 1.122 MB and a mean CPU inference latency of 0.626 ± 0.010 ms per sample after GRF preprocessing. The compact model size and low inference latency support computationally scalable post-acquisition processing of standardised GRF trials.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Leakage-Resistant Evaluation of Gait Mat and Multisensor Biomechanical Features for Knee Osteoarthritis Screening: A Subject-Level Data Integrity Study.Bioengineering (Basel, Switzerland) · 2026
- Robustness and Interpretability of Deep Learning on Raw Gait Marker Trajectories for Osteoarthritis ClassificationApplied Sciences · 2026
- Prediction of Running Anteroposterior Ground Reaction Force From the Vertical Component Through a Deep Learning Approach.Journal of applied biomechanics · 2026
- GaitFM: A Cross-Modal Foundation Model for Wearable Gait AssessmentarXiv · 2026
- Deep Learning-Based Temporal Gait Analysis Using a Smartphone IMU in Older Adults with and Without Non-Specific Low Back Pain.Bioengineering (Basel, Switzerland) · 2026
- Retrieval-Augmented Generation for Clinical Decision Support in Gait Analysis: A Proof-of-ConceptarXiv · 2026