Nanoparticle-induced interference with common in vitro assays: a systematic review.
Kunwar Anshumaan Singh, Abhishek Dubey, Veronica Tisato, Sunil Choudhary, Donato Gemmati, Swati Singh, Harshita Tiwari, Ashish Verma,
Department of Biotechnology, Bundelkhand University, Jhansi, Uttar Pradesh, India. · Centre Haemostasis and Thrombosis, University of Ferrara, Ferrara, Italy.
Key points
From the paper's conclusion- Consistent with prior population-level literature surveys, not restricted to this review’s eligibility-filtered cohort, the proportion of nanotoxicology publications omitting interference controls has been reported to fall from over 90% before 2014 to approximately 45% by 2021–2024, underscoring the reporting gap that motivated this review’s interference-control eligibility criterion.
Abstract
BACKGROUND: Engineered nanomaterials (NMs) are widely tested for biological safety using standard colorimetric, fluorometric, and enzymatic in vitro assays. However, the unique physicochemical properties of NMs, including strong optical activity, high surface-to-volume ratios, and surface reactivity, create a high potential for systematic, often unrecognized interference with these assays. OBJECTIVES: This systematic review sought to i) provide a comprehensive catalogue of reported cases of NM-induced assay interference, ii) quantify interference severity and direction by NM type and assay system, iii) synthesize reported physicochemical characteristics associated with assay interference, and iv) provide evidence-based recommendations for mitigation. METHODS: A systematic search of PubMed, Web of Science, and Scopus (2006-2026) identified 52 eligible records for the evidence synthesis, comprising primary experimental or method-validation studies together with contextual evidence. Data were extracted on NM composition, size, surface chemistry, assay type, interference mechanism, and effect magnitude. Interference severity was scored semi-quantitatively (0-3). A systematic narrative synthesis was performed. RESULTS: Interference was documented across multiple nanomaterial categories and assay platforms represented in the evidence matrix, with the extent of evidence varying among individual nanomaterial-assay combinations. Carbon-based nanomaterials demonstrated interference across several commonly used viability assays, although the concentrations and experimental conditions associated with interference varied substantially among studies. Silver NPs exhibited a strong LDH interference due to protein adsorption and ROS-mediated deactivation. The iron oxide NPs showed concentration-dependent optical interference across the experimental spectral ranges examined in the contributing studies. Cytokine ELISA tests were vulnerable to cytokine sequestration by TiO2, SiO2 and cationic NPs. Consistent with prior population-level literature surveys, not restricted to this review's eligibility-filtered cohort, the proportion of nanotoxicology publications omitting interference controls has been reported to fall from over 90% before 2014 to approximately 45% by 2021-2024, underscoring the reporting gap that motivated this review's interference-control eligibility criterion. CONCLUSION: NM-induced assay interference is pervasive, NM-specific, assay-specific, and concentration-dependent. No universal correction exists; each NM-assay combination requires individual validation. A standardized five-step interference testing workflow and reporting checklist are proposed to improve reproducibility in nanotoxicology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Interference of Microplastics with MTT and XTT Cell Viability Assays.ACS omega · 2026
- Why Sensors Fail in Biological Samples: Fouling, Blocking, Matrix Effects and Prevention SolutionsInternational Journal of Molecular Sciences · 2026
- Nanomaterial-Based Biosensors: Sensing Mechanisms, Performance Determinants, and ApplicationsJournal of Nanotheranostics · 2026
- Nanozymes as Heterogeneous Catalysts: In Operando Aggregation and Altered Apparent Substrate Affinity Affect Catalytic Properties and Immunoassay Reliability.ACS applied materials & interfaces · 2026
- When characterization misrepresents function: limits of analytical inference in nanomaterials.Analytical and bioanalytical chemistry · 2026
- Carbon- and polymer-integrated colloidal systems for biosensing: interfacial mechanisms, performance trade-offs, and applicationsFrontiers in Chemistry · 2026