Establishment of a robot-assisted ex vivo active shoulder simulator.
Alina Albert, Jane Gehling, Julia Sußiek, Willi Engelmann, Jens Wermers, J Christoph Katthagen
Biomechanics Laboratory, Department of Trauma, Hand and Reconstructive Surgery, University Hospital, Münster, Germany. · Department of Engineering Physics, Münster University of Applied Sciences, Steinfurt, Germany.
Key points
From the paper's conclusion- Conclusion This study demonstrates the feasibility of a robot-assisted ex vivo active shoulder simulator that combines muscle-driven motion with robotic load and constraint management.
Abstract
BACKGROUND: Stable, repeatable, muscle-driven shoulder simulation remains difficult to achieve ex vivo, although it is essential for studying clinically relevant variables such as joint reaction forces, glenohumeral translations, and joint torques that cannot be measured directly during dynamic motion in vivo. METHODS: A robot-assisted active shoulder simulator (RAASS) was developed in which six cable-driven actuators applied forces to the rotator cuff and deltoid muscle group. An industrial robot maintained defined boundary conditions and recorded synchronized kinetic and kinematic data during active scapular-plane glenohumeral abduction in 19 fresh-frozen cadaveric shoulders. Closed-loop force control was used to regulate actuator loading. Internal rotation and horizontal adduction were constrained to 0°. Translational force targets maintained joint compression while muscle force ratios were updated across the range of motion. RESULTS: Active glenohumeral abduction to 60° was successfully reproduced in all specimens. The robot compensated for emerging torques and external loads, allowing the muscle actuators to remain the primary drivers of motion. Mean total muscle force increased significantly with abduction angle, from 81 ± 36 N/kg at 20° to 107 ± 28 N/kg at 60°. Superior translation increased significantly with abduction, whereas posterior and medial translations showed no significant angle-dependent changes. Horizontal adduction torque increased from 20° to 40° and remained elevated at 60°, and internal rotation torque reached its greatest magnitude at 40°. CONCLUSION: This study demonstrates the feasibility of a robot-assisted ex vivo active shoulder simulator that combines muscle-driven motion with robotic load and constraint management. Beyond enabling controlled active abduction, the framework provides continuous, synchronized measurement of muscle forces, translations, torques, and kinematics. It allows the robot to serve as an active load-application and compensation interface. This represents a methodological advance for investigating shoulder stability, joint loading, and more complex dynamic shoulder motions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assist-as-Needed Control for Upper Limb Rehabilitation Using a Learned Passive Interaction Force Reference.Biomimetics (Basel, Switzerland) · 2026
- Evaluation of shoulder-support exoskeletons during simulated laparoscopic surgery across representative shoulder postures.Ergonomics · 2026
- Exploring the Muscle-Tendon Biomechanics and Load Mitigation of a Passive Shoulder Exoskeleton During Overhead Work.IEEE transactions on bio-medical engineering · 2026
- Dislocation Analysis on Bio-inspired Open Hip Joint with Active-and-Passive Stabilizers.Bioinspiration & biomimetics · 2026
- Design and Experimental Evaluation of a Shoulder Assistive Exoskeleton for Insulator ReplacementSensors · 2026
- Multidomain Electromechanical Finite Element Modeling of Biomimetic Muscle-Driven Robots Undergoing Large DeformationJournal of Marine Science and Engineering · 2026