The value of terahertz three-dimensional tomography for the differential diagnosis of tumor tissue and normal tissue in lung cancer nude mice.
Jin Zhu, Yang Li, Xiaoxue Zhang, Siqi Yin, Juntai Xu, Zhuang Yu, Shengnan Ren, Zhaoxin Guo,
Qingdao Medical College, Qingdao University, Qingdao, Shandong, China. · Oncology Department, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China.
Key points
From the paper's conclusion- CCK-8 and live/dead staining supported the biocompatibility of 40 μg/mL GNRs under the tested conditions. In vivo THz imaging showed higher tumor-region signals in the GNR-treated groups. At 0.5 THz, the model-specific tumor-to-adjacent skin/subcutaneous ROI contrast ratio in the LUSC group was 36:1 after GNR treatment and 22:1 in the untreated control; The contrast ratio of the GNR-treated LUSC group is 25:1, while that of the untreated control group is 19:1. Among the tested frequency bands, 0.5 THz provided the clearest image contrast. Contrast decreased markedly in paraffin-embedded tissues (approximately 2:1), and spectral differences in routine 5 μm human sections were obscured by the glass substrate. These findings support proof-of-concept signal enhancement in a subcutaneous xenograft model but do not establish a clinical tumor-to-normal-lung contrast ratio.
Abstract
INTRODUCTION: To investigate the value of terahertz (THz) spectroscopy combined with gold nanorods (GNRs) in the differential diagnosis of lung squamous cell carcinoma (LUSC) and lung adenocarcinoma (LUAD). METHODS: Tumor-bearing nude mouse models were established using GNR-treated A549 (LUAD) and NCI-H520 (LUSC) cells. Reflective THz 3D imaging and transmission THz time-domain spectroscopy (THz-TDS) systems, together with CT imaging and pathological validation, were employed to analyze the THz spectral characteristics of in vivo tumors, paraffin-embedded tissues, and thin sections. RESULTS: CCK-8 and live/dead staining supported the biocompatibility of 40 μg/mL GNRs under the tested conditions. In vivo THz imaging showed higher tumor-region signals in the GNR-treated groups. At 0.5 THz, the model-specific tumor-to-adjacent skin/subcutaneous ROI contrast ratio in the LUSC group was 36:1 after GNR treatment and 22:1 in the untreated control; The contrast ratio of the GNR-treated LUSC group is 25:1, while that of the untreated control group is 19:1. Among the tested frequency bands, 0.5 THz provided the clearest image contrast. Contrast decreased markedly in paraffin-embedded tissues (approximately 2:1), and spectral differences in routine 5 μm human sections were obscured by the glass substrate. These findings support proof-of-concept signal enhancement in a subcutaneous xenograft model but do not establish a clinical tumor-to-normal-lung contrast ratio. DISCUSSION: Under the tested conditions, GNR treatment was associated with higher THz signals in subcutaneous LUSC and LUAD xenografts. The mechanism and clinical performance remain unestablished; the approach should be regarded as proof-of-concept and as a potential complement to, rather than a replacement for, standard histopathology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rapid Glioma Subtype Classification Using Label-Free Terahertz Time-Domain Spectroscopy and Hierarchical Machine Learning.Journal of biophotonics · 2026
- Terahertz-based prognostic framework for glioma: from spectral features to patient-level prognostic assessment.npj biomedical innovations · 2026
- Graphene-based terahertz antenna with enhanced backscatter sensitivity for early breast cancer localizationNano Trends · 2025
- Label-free wide-field imaging of brain tumors using near-infrared endogenous fluorescence and reflectance normalization.Journal of biomedical optics · 2026
- Application of terahertz spectroscopy and imaging techniques in biomedicineiScience · 2025
- Deep Learning-Assisted Terahertz Metasurface Biosensing for Rapid Ex Vivo Molecular Assessment of Diffuse Glioma Frozen Sections.ACS sensors · 2026