Abstract
Introduction The cortical thickness (Ct.Th) of the mouse tibia midshaft is a good predictor of the failure load (FL_FE). Validated micro-computed tomography (micro-CT)-based micro-finite element (micro-FE) models have shown that the loading direction affects the FL_FE. Our aim in this study was to investigate whether Ct.Th is a good predictor of FL_FE under varying loading directions in ovariectomised mice, half of which were subjected to external mechanical loading over a two-week period. Methods The tibiae of eleven ovariectomised C57BL/6 mice at ages 18 and 20 weeks were scanned with micro-CT. Six of the mice underwent external, controlled mechanical loading to stimulate bone apposition at age 19 weeks. The Ct.Th was measured in the bone midshaft (1-mm thick region). Micro-FE models were generated based on segmented micro-CT images. Three models using unitary loads were linearly combined to simulate a range of loading directions spanning different tilt angles from the inferior–superior axis and different azimuthal rotations around the inferior–superior axis, leading to 504 loading directions per mouse at each time point. The minimum principal strain was calculated and used to estimate the failure load by linearly scaling the resultant strain until 10% of the nodes reached the critical strain level of −14,420 με. Linear mixed-effects models were fitted to investigate the correlation between Ct.Th and FL_FE at each loading direction. Results Ct.Th was strongly correlated with FL_FE across all tested loading directions (R 2 m range: 74%–92%), but following False Discovery Rate-correction, only 57 of the 504 loading directions remained significant (q < 0.05). This means that Ct.Th was a strong statistically significant predictor of FL_FE in only 11% of all the loading cases examined. These significant loading directions formed a regional range of loading parameters within the loading cone that incorporated the loading direction associated with the strongest predictive relationship (θ = 10°, ϕ = 200°, R 2 m = 92%). In comparison, the nominal axial loading direction (θ = 0°, ϕ = 0°) had an R 2 m of 86%. Discussion These results indicate that Ct.Th may serve as a practical surrogate estimation of FL_FE, saving computational resources, as long as any loading direction deviations from the nominal axial loading direction fall within this significant regional parameter range.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Micro-CT-derived nonlinear micro-finite element estimation of compressive fracture load in murine vertebrae: a pilot feasibility study in sclerostin antibody-treated and control mice.Medical engineering & physics · 2026
- Bone Response to Mechanical Loading is Highly Heritable and Correlates with Osteocyte Lacunar Morphology in Genetically Diverse Mouse Strains.bioRxiv : the preprint server for biology · 2026
- A study on the changes in the microstructure of trabecular bone and the biomechanical properties in patients with osteoporotic fractures and the correlation between them.Frontiers in medicine · 2026
- Altered tissue-to-fibril strain transfer in cortical bone from juvenile female Klotho-deficient mice.Bone · 2026
- Site-Specific and Diet-Dependent Genetic Architecture of Trabecular Bone in Male BXD Recombinant Inbred Mice.bioRxiv : the preprint server for biology · 2026
- Differential Adaptation of Osteocyte Lacunar Morphology at Bone (Re)modeling Sites under Mechanical Loading and Pharmacological Therapies in a Mouse Model of OsteoporosisbioRxiv · 2026