Frontiers in Bioengineering and Biotechnology

Relationship between cortical bone thickness and failure load in the mouse tibia tested in different loading directions

Saira Mary Farage-O’Reilly, Vee San Cheong, Enrico Dall’Ara

Key points

From the paper's conclusion
  • These significant loading directions formed a regional range of loading parameters within the loading cone that incorporated the loading direction associated with the strongest predictive relationship (θ = 10°, ϕ = 200°, R 2 m = 92%).

Abstract

Introduction The cortical thickness (Ct.Th) of the mouse tibia midshaft is a good predictor of the failure load (FL_FE). Validated micro-computed tomography (micro-CT)-based micro-finite element (micro-FE) models have shown that the loading direction affects the FL_FE. Our aim in this study was to investigate whether Ct.Th is a good predictor of FL_FE under varying loading directions in ovariectomised mice, half of which were subjected to external mechanical loading over a two-week period. Methods The tibiae of eleven ovariectomised C57BL/6 mice at ages 18 and 20 weeks were scanned with micro-CT. Six of the mice underwent external, controlled mechanical loading to stimulate bone apposition at age 19 weeks. The Ct.Th was measured in the bone midshaft (1-mm thick region). Micro-FE models were generated based on segmented micro-CT images. Three models using unitary loads were linearly combined to simulate a range of loading directions spanning different tilt angles from the inferior–superior axis and different azimuthal rotations around the inferior–superior axis, leading to 504 loading directions per mouse at each time point. The minimum principal strain was calculated and used to estimate the failure load by linearly scaling the resultant strain until 10% of the nodes reached the critical strain level of −14,420 με. Linear mixed-effects models were fitted to investigate the correlation between Ct.Th and FL_FE at each loading direction. Results Ct.Th was strongly correlated with FL_FE across all tested loading directions (R 2 m range: 74%–92%), but following False Discovery Rate-correction, only 57 of the 504 loading directions remained significant (q < 0.05). This means that Ct.Th was a strong statistically significant predictor of FL_FE in only 11% of all the loading cases examined. These significant loading directions formed a regional range of loading parameters within the loading cone that incorporated the loading direction associated with the strongest predictive relationship (θ = 10°, ϕ = 200°, R 2 m = 92%). In comparison, the nominal axial loading direction (θ = 0°, ϕ = 0°) had an R 2 m of 86%. Discussion These results indicate that Ct.Th may serve as a practical surrogate estimation of FL_FE, saving computational resources, as long as any loading direction deviations from the nominal axial loading direction fall within this significant regional parameter range.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers