Biomechanical analysis of maxillary incisor intrusion with clear aligners under different periodontal conditions: a finite element analysis.
Qiuying Li, Yidan Zhang, Bowen Xu, Linna Bai, Kai Yang
Department of Orthodontics, Beijing Stomatological Hospital, Capital Medical University, Beijing, China.
Key points
From the paper's conclusion- Clear aligners produce maxillary incisor intrusion with concurrent tipping. Lateral incisors show higher intrusion efficiency but endure greater mechanical stress than central incisors. Alveolar bone loss exacerbates both tipping tendency and stress. For patients with alveolar bone loss exceeding one-third, the intrusion increment is recommended to be limited to 0.15 mm.
Abstract
OBJECTIVES: To investigate the biomechanical effects and determine the optimal increment for maxillary incisor intrusion using clear aligners across three periodontal conditions via finite element analysis (FEA). MATERIALS AND METHODS: Nine FE models were created in a 3 × 3 design simulating three periodontal states (M1: normal bone level; M2: one-third alveolar bone loss; M3: one-half alveolar bone loss) combined with three intrusion increments (0.10, 0.15, and 0.20 mm). Anterior tooth displacement, root von Mises stress, and periodontal ligament (PDL) maximum compressive stress were analyzed. RESULTS: Tooth displacement and mechanical stresses escalated with greater bone loss and larger increments. Central incisors experienced more pronounced tipping, whereas lateral incisors achieved greater vertical intrusion. Consequently, lateral incisors endured higher stresses; their PDL stress was approximately double that of central incisors. While central incisor intrusion efficiency increased proportionally with increment, lateral incisors in M2 and M3 states demonstrated higher efficiency at the 0.15-mm increment (peaking at 92.0%) than at 0.20 mm. In the M3 state, increasing the increment from 0.10 to 0.20 mm sharply amplified lateral incisor root stress (2.96-8.18 MPa) and PDL stress (0.056-0.114 MPa). CONCLUSION: Clear aligners produce maxillary incisor intrusion with concurrent tipping. Lateral incisors show higher intrusion efficiency but endure greater mechanical stress than central incisors. Alveolar bone loss exacerbates both tipping tendency and stress. For patients with alveolar bone loss exceeding one-third, the intrusion increment is recommended to be limited to 0.15 mm.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of residual extraction space and torque overtreatment on mandibular incisor intrusion with clear aligners: a finite element analysis.BMC oral health · 2026
- Effect of additional mechanics used in intrusion with clear aligners on the movement of mandibular incisors: a finite element analysisBMC Oral Health · 2026
- Biomechanical effects of varying intrusion-to-retraction ratios on anterior tooth displacement during extraction space closure with clear aligners: an iterative finite element analysis.The Saudi dental journal · 2026
- Biomechanical analysis of retracting maxillary incisors using clear aligners with palatal mini-implants in extraction cases: a finite-element analysis.BMC oral health · 2026
- Effects of clear aligner-assisted miniscrew intrusion in mandibular anterior teeth: a three-dimensional finite element study.BMC oral health · 2026
- Apical alveolar bone thickness predicts intrusion accuracy and proclination risk of mandibular incisors in clear aligner therapy: a pilot study.BMC oral health · 2026