UV-derived scattering as a high-throughput readout for adeno-associated virus-like particle separation screenings.
Giulia Polazzo, Malte Schwarzer, Jürgen Hubbuch
Institute of Process Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
Key points
From the paper's conclusion- Overall, UV-derived scattering provides a rapid, scalable first-line readout for comparing separation conditions and reducing the number of samples requiring capsid-specific and structural characterization.
Abstract
Virus-like particles (VLPs), including those derived from adeno-associated virus (AAV), are increasingly investigated for vaccination, capsid engineering, and gene-delivery applications. Although precipitation and aqueous two-phase separation (ATPS) represent promising alternatives to adsorption-based capture, their optimization is limited by the lack of rapid analytical methods suitable for complex process samples. Here, VP3-only AAV5 VLPs produced in Escherichia coli were used as a model system to evaluate UV-derived light scattering as a high-throughput separation readout. Blank-corrected absorbance at 320 nm was used as a relative descriptor of particulate-associated scattering, while scattering-corrected absorbance at 280 nm monitored the soluble biomolecular fraction. During PEG precipitation, A320 showed condition-dependent agreement with anti-AAV5 ELISA, with the closest correspondence for PEG4000 and increasing divergence at lower PEG molecular weights. Capsid-spiking experiments further showed that dispersed intact capsids alone contributed only marginally to A320, indicating that the signal primarily reflects larger scattering-active structures accompanying capsid depletion. The workflow enabled screening and analysis of 170 precipitation and PEG/phosphate ATPS conditions in biological duplicate within 3 days. Low-molecular-weight PEG systems provided stronger separation between soluble biomolecular material and particulate-associated scattering. In PEG400 ATPS, pH altered the distribution of scattering-active material and capsids between the liquid phases and interphase, whereas selected precipitation conditions showed higher recovery of assembled capsids after resolubilization than ATPS, at the expense of lower impurity removal. Overall, UV-derived scattering provides a rapid, scalable first-line readout for comparing separation conditions and reducing the number of samples requiring capsid-specific and structural characterization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Continuous Capture of Recombinant Adeno-Associated Virus Particles Using Twin-Column CaptureSMB.Biotechnology and bioengineering · 2026
- Mechanisms of Adeno-Associated Virus Serotype 9 Vector Characterization and Quality Control through Solid-State NanoporesACS Nano · 2025
- Assessing Precision and Accuracy in Adeno-Associated Virus Capsid Ratio Determination Using Post-Ultracentrifugation CsCl Density Gradient Profiling and Multimodal Detection Techniques.Human gene therapy · 2026
- Mechanistic Insights Into Host Cell Protein Co-Purification With Adeno-Associated Virus Vectors During the Density-Gradient Ultracentrifugation Process.Biotechnology and bioengineering · 2026
- High-resolution separation and quantification of dual-AAV drug products by density gradient equilibrium analytical ultracentrifugation.Gene therapy · 2026
- Quantum Cascade Laser-Based Mid Infrared Spectroscopy (QCL-MIDIR) for Real-Time Monitoring of Capsid Concentration and Empty/Non-Empty Percentage of Adeno-Associated Viral Particles.Analytical chemistry · 2026