Polymer-based biopotential electrode-leadwire prototype for ECG sensing during X-ray and CT examinations.
Marek Penhaker, Jan Polomik, Jan Kijonka, Jaroslav Stejskal, Martin Cerny, Dominik Vilimek, Peter Kneppo, Ladislav Janousek,
Faculty of Electrical Engineering and Computer Science, VSB - Technical University of Ostrava, Ostrava Poruba, Czechia. · Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Prague, Czechia.
Key points
From the paper's conclusion- The results demonstrate the feasibility of uninterrupted ECG monitoring during radiological examinations without introducing image artifacts associated with conventional metallic ECG systems.
Abstract
INTRODUCTION: Continuous ECG monitoring during X-ray and CT examinations is crucial for critically ill patients; however, standard Ag/AgCl electrodes and metallic leadwires generate image artifacts that may compromise diagnostic quality. This study aimed to develop and evaluate a non-metallic, radiolucent polymer-based ECG electrode-leadwire system enabling artifact-free ECG sensing during radiological imaging. MATERIALS AND METHODS: Biocompatible conductive polymers, polypyrrole (PPy) and polyaniline (PANI), were polymerized in situ onto cotton and carbon substrates to fabricate dry textile electrodes and carbon-fiber leadwires. The polymer-based electrode-leadwire prototype was compared to standard Ag/AgCl electrodes and metallic leadwires in terms of ECG signal quality and radiolucency. Radiolucency was evaluated using CT and X-ray imaging on phantom models and a veterinary subject, with CT conspicuity quantified by Hounsfield unit attenuation difference |ΔHU|. ECG signal quality was assessed using complementary time-domain metrics, including Pearson correlation, root-mean-square error (RMSE), mean absolute error (MAE), signal-to-noise ratio (SNR), and baseline variability, together with the frequency-domain metric magnitude-squared coherence (MSC), under static and simulated CT motion conditions. RESULTS: PPy-coated cotton electrodes demonstrated high agreement with Ag/AgCl references with Pearson correlation coefficients ranging from 0.93 to 0.99 and magnitude-squared coherence values ranging from 0.81 to 0.99 across all tested configurations. Relative R-wave amplitude deviations remained below 13%. PANI-coated carbon-fiber leadwires exhibited low resistance (≈11 Ω/m) and stable signal transmission. CT and X-ray imaging showed complete radiolucency of conductive polymer components, with only faint visibility of auxiliary non-conductive materials under high-contrast CT settings. Simulated CT table motion introduced only minor signal degradation with RMSE values ≤0.05 mV and preserved signal-to-noise ratio and baseline stability within ranges commonly considered acceptable for clinical ECG monitoring. CONCLUSION: The proposed dry, non-metallic polymer-based ECG prototype provides artifact-free ECG monitoring during X-ray and CT imaging while preserving clinically relevant signal quality. The results demonstrate the feasibility of uninterrupted ECG monitoring during radiological examinations without introducing image artifacts associated with conventional metallic ECG systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Systematic Benchmarking of a Noise‐Tolerant Conductive Hydrogel Electrode for Epidermal BioelectronicsAdvanced Science · 2025
- Laser-Engraved Porous Breathable Hydrogels for Wearable Electrocardiogram Monitoring.Langmuir : the ACS journal of surfaces and colloids · 2026
- Performance comparison of conductive textile electrodes in ECG monitoringFrontiers in Bioengineering and Biotechnology · 2026
- Conducting polymers for implantable neural electrodes in brain-computer interfaces.Journal of materials chemistry. B · 2026
- Strain-Resilient Integrated Conductive Elastomer with Stable Conductivity via Grafting and Blending for Flexible Sensing and Self-Adhesive Dry Electrocardiogram Monitoring Electrode.ACS applied materials & interfaces · 2026
- BioShield-12: A 3D-Printed Conformal Chest Shield for Wireless 12-Lead ECG Acquisition.Sensors (Basel, Switzerland) · 2026