Changes of bladder urodynamics after combined pelvic floor muscle training and intravaginal stimulation in women with stress urinary incontinence: a retrospective cohort study.
Hui-Hsuan Lau, Cheng-Yuan Lai, Ming-Chun Hsieh, Hsien-Yu Peng, Dylan Chou, Tsung-Hsien Su, Jie-Jen Lee, Tzer-Bin Lin
Division of Urogynecology, Department of Obstetrics and Gynecology, Mackay Memorial Hospital, Taipei, Taiwan. · Institute of Biomedical Sciences, Mackay Medical College, New Taipei, Taiwan.
Key points
From the paper's conclusion- PFMT + IVS appears to maintain adequate outlet resistance during storage while permitting effective relaxation during voiding, thereby preserving voiding pressure and flow. Although total work per voiding cycle increased, work normalized to voided volume remained unchanged, suggesting preserved voiding efficiency.
Abstract
INTRODUCTION: Sling implantation increases bladder outlet resistance and consequently elevates voiding workload in patients with stress urinary incontinence (SUI). This study investigated whether a non-invasive approach-pelvic floor muscle strengthening combined with intravaginal stimulation (PFMT + IVS)-modulates voiding work through alterations in outlet resistance. METHODS: Cystometric data from 20 female patients with SUI who completed a home-based PFMT + IVS program were retrospectively analyzed. The intervention consisted of biofeedback-assisted pelvic floor muscle training and intravaginal electrical stimulation (20 min each, twice weekly for 3 months). Symptom severity and quality of life were assessed using the Urogenital Distress Inventory-6 (UDI-6) and Incontinence Impact Questionnaire-7 (IIQ-7). Urodynamic parameters and pressure-volume analysis (PVA) indices were evaluated before and after treatment. RESULTS: Following PFMT + IVS, patients showed significant reductions in UDI-6 (p < 0.001; N = 20) and IIQ-7 scores (p < 0.001; N = 20). Voided volume (Vvoid; p = 0.042), voiding time (Tvoid; p = 0.028), and the pressure-volume trajectory area (Apv; p = 0.044), a surrogate of voiding work, were significantly increased. In contrast, no significant changes were observed in voiding resistance (Rvoid; p = 0.089), voiding pressure (Pvoid; p = 0.306), or flow rate (Fvoid; p = 0.271). The increase in Apv correlated positively with the increase in Vvoid (r = 0.450, p = 0.046), and the increase in Vvoid correlated with prolonged Tvoid (r = 0.665, p = 0.001). CONCLUSION: PFMT + IVS appears to maintain adequate outlet resistance during storage while permitting effective relaxation during voiding, thereby preserving voiding pressure and flow. Although total work per voiding cycle increased, work normalized to voided volume remained unchanged, suggesting preserved voiding efficiency.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating Intravaginal and Transvaginal Electrical Stimulation Techniques for Urinary Incontinence: A Systematic Review with Meta-analysis.The Eurasian journal of medicine · 2026
- Effects of various pelvic floor muscle training forms and combined regimens on muscle strength, function, and recurrence rate in post-vaginal delivery stress urinary incontinence patients.Clinics (Sao Paulo, Brazil) · 2026
- Pelvic muscle training and electrostimulation to treat weak pelvic floor: a multicentre-randomised parallel group trialEuropean Journal of Obstetrics & Gynecology and Reproductive Biology · 2026
- Novel Telerehabilitation Interventions for Stress Urinary Incontinence : A Systematic Review of Randomised Controlled Trials.Archives of physical medicine and rehabilitation · 2026
- Post-Surgical Evaluation in Stress Urinary Incontinence by Transperineal Ultrasound and Quality of Life Questionnaire-A Retrospective Study.Diagnostics (Basel, Switzerland) · 2026
- Anatomy of urethro-vesical segment and vaginal microbiota: is there any connection at stress urinary incontinence?Frontiers in medicine · 2026