Evaluating the accuracy of table tennis 3D markerless motion capture based on two video cameras: a pilot study
Ziwei Cao, Ze Zhang, Yi Xiao
Shanghai University of Sport
Key points
From the paper's conclusion- Conclusion (1) The markerless system, though slightly less accurate, can also capture joint motion data. (2) Increasing baseline distance improves accuracy when the camera position is fixed. (3) With a fixed baseline distance, the system with the RF camera position outperforms the RR position in accuracy.
Abstract
Introduction This pilot study presents a 3D markerless motion capture system for table tennis using binocular cameras, based on the OpenPose framework and linear triangulation to obtain 3D joint motion data. The system’s accuracy was compared to a marker-based system, and the impact of different camera. Methods A comparative experiment was conducted between the proposed markerless system and a marker-based reference system. Three camera configurations were tested: RR-100 (right-right placement, 100 cm baseline), RR-145 (right-right placement, 145 cm baseline), and RF-100 (right-front placement, 100 cm baseline). Dynamic Time Warping (DTW) similarity of elbow joint angle curves was used as the primary accuracy metric, and statistical comparisons (p-values) were performed to identify significant differences in system errors across configurations. Results (1) At a camera position of RR-100, the DTW similarity of the elbow joint angle curves between the markerless and marker-based systems was 0.941, 0.719, and 0.854, respectively, similar to the marker-based system. The DTW similarity reached 0.948, 0.730, and 0.887 for RR-145 and 0.949, 0.729, and 0.860 for RF-100. (2) Significant differences in system errors were found at varying baseline distances with L = RR, showing better accuracy at 145 cm (p < 0.01). (3) Significant differences in errors were found with L = RF and a 100 cm baseline, with better accuracy at RF (p < 0.01). Conclusion (1) The markerless system, though slightly less accurate, can also capture joint motion data. (2) Increasing baseline distance improves accuracy when the camera position is fixed. (3) With a fixed baseline distance, the system with the RF camera position outperforms the RR position in accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of Different Marker Set Configurations on Tennis Stroke Recognition Performance: A Three-Dimensional Kinematic Study Based on MiniRocket.Sensors (Basel, Switzerland) · 2026
- Markerless Motion Capture in Sport and Exercise: A Systematic Review of Applications, Validity, and ReliabilityApplied Sciences · 2026
- Blink Behaviour, Pupil Diameter, and Technical Performance in Elite Male Table Tennis Players: A Wearable Eye-Tracking Study.Sports (Basel, Switzerland) · 2026
- Assessing the accuracy of in-stadium and portable multi-camera markerless motion capture for baseball pitching kinematics and kineticsJournal of Sports Sciences · 2025
- TrackStudio: An integrated toolkit for markerless trackingPLoS ONE · 2026
- Evaluation of sparse inertial sensor configurations for tennis stroke classification: balancing performance and wearability.Computer methods in biomechanics and biomedical engineering · 2026