The size effect on mechanical and permeability properties of porous bone structures fabricated by selective laser melting
Yongtao Lyu, Hongrui Cao, Peiqi Jing, Yunfei Lan, Sergei Bosiakov, Haytham Elgazzar, Guangyu Li, Yadong Liu
Dalian University of Technology · Belarusian State University
Key points
From the paper's conclusion- This study confirms that unit cell size profoundly impacts both the mechanical integrity and permeability of porous bone structures: smaller unit cells are recommended for applications prioritizing high compressive strength, whereas larger unit cells are more favorable for enhanced fluid transport.
Abstract
Porous structures are extensively utilized in bone tissue engineering for their lightweight nature, high strength-to-weight ratio, and superior energy absorption capacity. However, achieving optimal scaffold performance through precise dimension control remains a significant design challenge. This study systematically investigates the effect of unit-cell size on the mechanical and fluid transport properties of porous bone structures, aiming to provide guidance for scaffold design. Various porous structures with controlled unit cell sizes were fabricated via Selective Laser Melting (SLM) and evaluated under compressive loading. A complementary finite element (FE) model was developed to simulate mechanical responses and extract equivalent elastic modulus and compressive strength, while computational fluid dynamics (CFD) simulations were conducted on 4 × 4 × 4 arrays to calculate permeability. Results demonstrate that the Gyroid unit cell exhibited the most uniform stress distribution among the three studied architectures (Cube, Octa, Gyroid), and reducing unit cell size effectively mitigated stress concentrations to enhance structural stability. At a constant porosity, the compressive strength of uniform porous structures decreased with increasing unit-cell size, whereas the elastic modulus showed relatively low sensitivity to size variation. Meanwhile, permeability increased markedly with increasing unit-cell size. This study confirms that unit cell size profoundly impacts both the mechanical integrity and permeability of porous bone structures: smaller unit cells are recommended for applications prioritizing high compressive strength, whereas larger unit cells are more favorable for enhanced fluid transport.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and Performance Evaluation of TPMS-Based Dual-Layer Gradient Porous Structures for Bone ScaffoldsJournal of Functional Biomaterials · 2026
- Biomechanical and Hydrodynamic Characterization of Gradient-Porosity Triply Periodic Minimal Surfaces Polyether Ether Ketone Scaffolds for Craniofacial Bone Defect Repair.The Journal of craniofacial surgery · 2026
- Decoupling Pore Size and Porosity in Sheet-Based TPMS Scaffolds: Assessing Early Osteogenesis via a Capture-Then-Differentiate Framework.International journal for numerical methods in biomedical engineering · 2026
- Decoupling pore size and porosity in Voronoi bone scaffolds: A multiphysics framework for early osteogenic evaluation.Journal of the mechanical behavior of biomedical materials · 2026
- 3D-Printed OsteoFlux Scaffolds with Radially Graded TPMS Structures.ACS applied bio materials · 2026
- Niti minimal surface porous scaffolds matching human bone characteristics: mechanical, permeability and osteogenic propertiesVirtual and Physical Prototyping · 2026