Frontiers in bioinformaticsOpen accessArtificial intelligence

HistoBreastCAD: an integrated deep learning framework for segmentation and multiclass classification of whole-slide breast histopathology images.

Oswaldo Celi-Vega, Yuliana Jiménez-Gaona, Patricio Corral-Dominguez, Ángel Gutiérrez, Zaida Socola-Barzallo

Departamento de Ciencias de La Computación, Universidad Técnica Particular de Loja, Loja, Ecuador. · Departamento de Química y Ciencias Exactas, Universidad Técnica Particular de Loja, Loja, Ecuador.

Computational · n=95

Key points

From the paper's conclusion
  • HistoBreastCAD therefore demonstrates the feasibility of integrating established deep learning components into a source-separated WSI-oriented digital pathology workflow.

Abstract

Breast cancer remains a major cause of cancer-related morbidity and mortality worldwide, and histopathological examination remains the diagnostic gold standard. This study presents HistoBreastCAD, an integrated deep learning framework that combines tissue-region segmentation, four-class histopathology classification, spatial mapping of predictions, and interactive whole-slide image (WSI) review. Segmentation was evaluated using WSI-grouped five-fold cross-validation, while classification used source-image-grouped five-fold cross-validation to prevent source-level data leakage. The final DeepLabV3+ L0 segmentation configuration achieved an out-of-fold micro-Dice of 0.8390, IoU of 0.7226, precision of 0.8278, and recall of 0.8505. For classification, EfficientNetB0 was the strongest individual model, while a frozen equal-weight soft-voting ensemble of EfficientNetB0 and ResNet18-GAP-attention achieved an accuracy of 0.8283 ± 0.0320 and macro-F1 of 0.8282 ± 0.0316, outperforming EfficientNetB0 in all five validation folds. An exploratory reader study using the 100 microscopy images from the held-out BACH test set showed moderate interobserver agreement between two pathologists (Cohen's κ = 0.5105; n = 95), whereas model-to-reader concordance was lower. The ensemble did not increase reader concordance relative to EfficientNetB0. HistoBreastCAD therefore demonstrates the feasibility of integrating established deep learning components into a source-separated WSI-oriented digital pathology workflow. However, external multi-institutional validation, adjudicated reader studies, and formal explainability assessment are required before claims of clinical generalizability or utility can be supported.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers