Real-world performance of a Japanese browser-based hearing test: large-scale online usage data and concordance with clinical speech audiometry
Shujiro Minami, Marie Shimanuki, Takanori Nishiyama, Hiroshi Nishimura, Masaru Tateda, Ken Kato, Haruo Yoshida, Hiroyuki Sasaki,
Key points
From the paper's conclusion- These data characterize the concordance of a non-English digital hearing assessment platform with clinical speech audiometry and provide the first estimates of its measurement error.
Abstract
Browser-based hearing tests offer a scalable alternative to clinic-based assessment, but most validated tools have been developed in English-speaking populations. The authors conducted a retrospective observational analysis of real-world use of a Japanese browser-based hearing test platform (April 2023–March 2026), complemented by a prospective multicentre paired sub-study against conventional clinical speech audiometry. The retrospective analysis included 8,022 unique users and 86,959 test executions across four modules: music perception (Montreal Battery of Evaluation of Musical Abilities); speech perception in quiet; speech in noise at +10, +5, and 0 dB signal-to-noise ratios (SNRs); and consonant identification. Completion rates of the full-length modules ranged from 43.7% to 85.8%. Speech perception in quiet showed pronounced upper-end clustering (41.0% of completed attempts and 57.9% of users scored ≥90%), whereas music perception was more broadly distributed (20.8% and 21.2%, ≥90%), and speech-in-noise accuracy fell progressively from a mean of 72.0% at +10 dB to 57.0% at 0 dB SNR, where no attempt reached 90%. These patterns persisted when the analysis was restricted to one attempt per user. Music perception correlated only modestly with all speech-related outcomes (Spearman ρ = 0.31–0.39). Repeat administration by the same user yielded intraclass correlation coefficients of 0.58–0.85 and a smallest detectable change of 17.6–35.8 percentage points. In the sub-study, 41 participants (25 unaided, 16 aided) completed the conventional 20-item 67-S word recognition test in a calibrated booth and, within days to weeks, the 20-item online check unsupervised on their own device. Agreement was moderate (Pearson r = 0.65, 95% CI [0.43, 0.80]; ICC(2,1) = 0.62, 95% CI [0.37, 0.78]), with a small negative bias (−6.2 percentage points, 95% CI [−10.8, −1.6]) and wide limits of agreement (−34.7 to +22.2). These data characterize the concordance of a non-English digital hearing assessment platform with clinical speech audiometry and provide the first estimates of its measurement error. They do not establish screening accuracy: no pure-tone reference, referral threshold, sensitivity, or specificity was evaluated, and the limits of agreement are too wide for individual-level clinical interpretation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design, Development, and Initial Evaluation of a Web-Based Music Ear-Training Assessment System in Higher EducationInformatics · 2026
- Preliminary Concurrent Validity of Abbreviated App-Based Frequency and Duration Pattern Tests in Normal-Hearing Adults.Audiology research · 2026
- Test-Retest Reliability and Preliminary Validation of Smartphone-Based Threshold and Categorical loudness Measures in Home Settings.Trends in hearing · 2026
- A Delphi-guided development and validation of a comprehensive auditory attention assessment tool (C-AAAT)Applied Neuropsychology Adult · 2026
- Validation of Non‐Soundproof Tablet Audiometry in Pediatrics: Comparison With Traditional AudiometryThe Laryngoscope · 2026
- Patient-reported benefit and speech perception in 24,570 hearing aid users: a nationwide study of the French Client-Oriented Scale of Improvement (COSI)medRxiv · 2026