Polarized light microscopy to quantify changes in the tympanic membrane microstructure in chronic otitis media
Jordan Villa, Diana Cobas, Joaquin Cury, Dayton Rand, Xiaodong Tan, Joseph Reynolds, Zohaib Ahmed, Grace E. Stutzmann,
Key points
From the paper's conclusion- Results TM sections from mice with chronic otitis media exhibited notable alterations in optical retardance at 28 days post-inoculation (DPI).
Abstract
Introduction Chronic otitis media (COM) induces progressive structural remodeling of the tympanic membrane (TM), beginning with epithelial hyperplasia and advancing to disruption of the organized collagen architecture that underlies its mechanical behavior. Loss of collagen integrity within the TM has been associated with an increased risk of retraction and perforation, yet no clinically available method directly assesses layer-specific TM structure in vivo . Polarization-sensitive optical coherence tomography (PS-OCT) has recently been proposed as a promising approach for evaluating TM microstructure, but it has not yet been applied to pathologic TMs. Quantitative polarized light microscopy (qPLM) of diseased TM sections provides disease-relevant biological support for future evaluation of PS-OCT in pathologic TMs. We aimed to measure changes in optical retardance of collagen layers in both normal and pathologic TMs. Methods Mice were intranasally inoculated with an upper respiratory pathogen to induce otitis media. Auditory brainstem responses were recorded before (baseline) and at 7 and 28 days post-inoculation (DPI) to confirm middle ear involvement. TMs from control and OM mice were harvested at 28 DPI, embedded in Araldite resin, and sectioned at 7 μm thickness. Optical retardance of TM collagen layers was quantified using polarized light microscopy. Polarized light microscopy for assessing the integrity of collagen structures was validated using harvested human TMs. Results TM sections from mice with chronic otitis media exhibited notable alterations in optical retardance at 28 days post-inoculation (DPI). Regions of structural alteration demonstrated a significantly reduced mean retardance (4.62 ± 1.34 nm) compared with adjacent, unaltered regions within the same TM (9.78 ± 0.95 nm). Control TMs exhibited comparable retardance values (9.16 ± 0.87 nm). Retardance in altered TM regions was significantly lower than both unaltered regions of the same TM and control TMs ( p < 0.05 for both comparisons). This is consistent with collagen disorganization and tissue degradation associated with otitis media. Induced heat damage in a human TM shows similar changes in retardance to those seen in mouse models of OM. Conclusions qPLM provides a robust method for evaluating TM structure following otitis media. Optical retardance was significantly reduced in regions classified as disrupted within COM TMs, consistent with progressive collagen degradation during disease. Once optimized, PS-OCT-equipped otoscopes may offer a valuable, clinically translatable approach for assessing TM layer integrity in vivo .
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optical Coherence Tomography for Quantitative Point-of-Care Ear Imaging.The Laryngoscope · 2026
- Spatiotemporal evolution of corneal biomechanical properties after cross-linking based on optical coherence elastography.Frontiers in bioengineering and biotechnology · 2026
- Polarized Light Microscopy for Quantitative Assessment of Sarcomere-Scale Structural Order in Cardiac Tissue.Journal of biophotonics · 2026
- Sound-Driven Motion of Human Cochlear Structures Depends on Organ of Corti Integrity.bioRxiv : the preprint server for biology · 2026
- Birefringence and depolarization characteristics of myelinated retinal nerve fibers assessed with polarization-sensitive optical coherence tomography.Japanese journal of ophthalmology · 2026
- Advances in the application of optical coherence elastography in ophthalmologyJournal of Innovative Optical Health Sciences · 2026