Diseases of aquatic organisms

Development of a minicollagen (ncol-2)-targeted qPCR assay for improved quantification of Enteromyxum leei.

Eun Gyeong Lee, Kyoung-Hui Kong, So-Ri Han, Myoung Sug Kim, Sung-Hyun Kim, Hyoung Jun Kim, Ki Hong Kim

Department of Aquatic Life Medicine, Pukyong National University, Busan 48513, Republic of Korea. · Pathology Research Division, National Institute of Fisheries Science, Pusan 46083, Republic of Korea.

Key points

From the paper's conclusion
  • This disparity demonstrates that ncol-2 effectively reduces copy-number variability associated with ribosomal gene duplication, providing a more biologically accurate and standardized molecular tool for improved quantification of E. leei in both diagnostic and epidemiological research.

Abstract

Enteromyxum leei is a significant myxosporean parasite associated with emaciation syndrome in cultured fish, particularly olive flounder Paralichthys olivaceus in Korea, that can lead to substantial economic losses. Accurate quantification of parasite load is crucial for monitoring disease progression and assessing infection intensity. While 18S rDNA-targeted quantitative PCR (qPCR) has been widely used, the inherent copy-number plasticity of ribosomal arrays across different developmental stages limits its precision for absolute quantification, often introducing unpredictable signal inflation. In this study, we developed and validated a novel qPCR assay targeting the minicollagen (ncol-2) gene, a putative low-copy structural gene expected to maintain a relatively stable genomic ratio per nucleus. The ncol-2 qPCR assay demonstrated high linearity (R2 = 0.999) and an amplification efficiency of 95.4% over a range of 102 to 107 copies μl-1, with a robust limit of detection (LoD95) of 8.57 copies μl-1. The assay showed high specificity with no cross-reactivity against other myxosporean parasites and exhibited acceptable repeatability across different real-time PCR platforms. Comparative analysis using 100 clinical samples revealed a strong correlation (r = 0.978) between the ncol-2 and 18S rDNA assays. Notably, copy numbers estimated by the ncol-2 assay were, on average, 29.68-fold lower than those from the 18S rDNA assay, with a marked sample-to-sample fluctuation (SD ± 13.8). This disparity demonstrates that ncol-2 effectively reduces copy-number variability associated with ribosomal gene duplication, providing a more biologically accurate and standardized molecular tool for improved quantification of E. leei in both diagnostic and epidemiological research.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers