Journal of Korean medical science

Screening for Left Ventricular Dysfunction in Sepsis Using a Smartphone ECG Analysis Application: A Multicenter Validation Study.

Yun Seong Park, Joonghee Kim, You Hwan Jo, Woon Yong Kwon, Kyoung Jun Song, Hui Jai Lee, Youngjin Cho, Ji Eun Hwang

Department of Emergency Medicine, Seoul National University College of Medicine, Seoul, Korea. · Department of Emergency Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.

Observational

Key points

From the paper's conclusion
  • AI-driven ECG analysis via a smartphone app provided a rapid, accessible, and accurate screening tool for LV dysfunction in sepsis and outperformed NT-proBNP. Its high NPV suggests potential utility for early risk stratification and for informing cautious hemodynamic management, although prospective studies are needed to define its role in sepsis treatment protocols.

Abstract

BACKGROUND: Sepsis-induced left ventricular (LV) dysfunction complicates fluid resuscitation, increasing the risk of pulmonary edema and worsening outcomes. Echocardiographic assessment is often delayed, and natriuretic peptides such as N-terminal pro-B-type natriuretic peptide (NT-proBNP) have limited diagnostic accuracy in this setting. We evaluated a smartphone-based electrocardiogram (ECG) analysis application for screening LV dysfunction in patients with sepsis. METHODS: In this multicenter retrospective observational study, we included 425 adult sepsis patients from three university hospitals who underwent both a 12-lead ECG and transthoracic echocardiography within 72 hours of emergency department admission. ECG images displayed on a monitor were photographed and analyzed using an artificial intelligence (AI)-based smartphone application (ECG Buddy™), which generated a quantitative digital biomarker for LV dysfunction (quantitative electrocardiogram scores for LV dysfunction [QCG-LVDys]). LV dysfunction was defined as a left ventricular ejection fraction ≤ 40%. The diagnostic performance of QCG-LVDys for detecting LV dysfunction was evaluated using area under the receiver operating characteristic curve (ROC-AUC). A predefined comparison with NT-proBNP was performed in the single center where NT-proBNP was routinely measured. RESULTS: In the overall multicenter cohort, QCG-LVDys showed high diagnostic performance for LV dysfunction, with an ROC-AUC of 0.901. Using an optimized threshold (37.35), QCG-LVDys achieved a sensitivity of 89.6%, specificity of 75.1%, and negative predictive value (NPV) of 97.5%. In the NT-proBNP subset, QCG-LVDys outperformed NT-proBNP (ROC-AUC 0.911 vs. 0.637, P < 0.001). Higher QCG-LVDys values were associated with increased lactate levels (P = 0.002) and 28-day in-hospital mortality (P < 0.001). CONCLUSION: AI-driven ECG analysis via a smartphone app provided a rapid, accessible, and accurate screening tool for LV dysfunction in sepsis and outperformed NT-proBNP. Its high NPV suggests potential utility for early risk stratification and for informing cautious hemodynamic management, although prospective studies are needed to define its role in sepsis treatment protocols.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers