Nationwide Harmonization Evaluation of Thyroid Function Tests Using External Quality Assessment Data: Utilization of Serum-Based In-House Quality Controls.
Hyun-Woo Lee, Hyung-Doo Park
Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Key points
From the paper's conclusion- The use of SIQCs was associated with improved comparability of TFT EQA results and enabled an exploratory EQA-based harmonization assessment. The proposed EQA-based framework demonstrated optimal harmonization for TSH but persistent comparability limitations for free T4 and total T3, supporting continuous nationwide monitoring and targeted harmonization efforts.
Abstract
BACKGROUND: Inter-assay variability in thyroid function tests (TFTs) may cause inconsistent clinical interpretation across laboratories. We investigated longitudinal trends in inter-laboratory variability and developed a quantitative framework for evaluating nationwide TFT harmonization using external quality assessment (EQA) data. METHODS: Ten years of TFT EQA data (2016-2025) from the Korean Association of External Quality Assessment Service were analyzed. Inter-laboratory CVs were compared between commercial quality controls and serum-based in-house quality controls (SIQCs). An exploratory harmonization evaluation was performed using 2024-2025 SIQC-based EQA data by calculating bias, CV, and total analytical error (TAE) at the sub-peer-group, peer-group, and analyte levels. TAE values were compared with biological variation-based total allowable error criteria and classified as optimal, desirable, minimum, or unacceptable harmonization. RESULTS: Inter-laboratory CVs were significantly lower with SIQCs than with commercial QCs for TSH (median, 11.0% vs. 13.0%), free T4 (11.6% vs. 15.3%), total T4 (3.1% vs. 7.6%), and total T3 (9.8% vs. 12.6%). At the analyte level, TSH achieved optimal harmonization in all four trials, with TAE values of 7.1%-8.2%. Free T4 showed minimum harmonization in all trials (TAE: 6.8%-8.8%), whereas total T3 showed minimum or unacceptable harmonization (TAE: 10.6%-14.1%). CONCLUSIONS: The use of SIQCs was associated with improved comparability of TFT EQA results and enabled an exploratory EQA-based harmonization assessment. The proposed EQA-based framework demonstrated optimal harmonization for TSH but persistent comparability limitations for free T4 and total T3, supporting continuous nationwide monitoring and targeted harmonization efforts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating feasibility of ferritin assay harmonisation with commutable proof-of-concept reference materials and EQA-based monitoring.Clinical chemistry and laboratory medicine · 2026
- Strengthening the interpretation of longitudinal EQA data through the sporadic inclusion of native human sera in general clinical chemistry.Frontiers in molecular biosciences · 2026
- Inter-platform variability of TgAb, TPOAb and TRAb immunoassays: analytical agreement and consequences for antibody positivity.Clinical chemistry and laboratory medicine · 2026
- A-153 Establishment of total T4 reference interval by Roche e 801 in a Singaporean populationClinical Chemistry · 2026
- A-326 Using laboratory data to support quality improvement in thyroid-stimulating hormone test utilization, tailored to clinical needsClinical Chemistry · 2026
- A geometric tensor-based computational framework for harmonizing thyroid function tests across laboratories with dissimilar reference intervals.Computer methods and programs in biomedicine · 2026