Nationwide Survey of Laboratory-Initiated Peripheral Blood Smear Review Practices in Korea: Criteria, Workload, and Reimbursement.
Hyunji Kim, Won Kyung Kwon, Sooyong Park, Daehyun Chu, Jin Jung, Jin Ju Kim, Jong-Mi Lee, Myungshin Kim
Department of Laboratory Medicine, Seoul National University Bundang Hospital and Seoul National University College of Medicine, Seoul, Korea. · U2 Medical Foundation, Seoul, Korea.
Key points
From the paper's conclusion- LIR practices in Korea have evolved toward simpler, analyzer-centered workflows; however, variability persists in terms of review criteria, workload, reporting, and reimbursements. Therefore, updated consensus recommendations and reimbursement policies are required.
Abstract
BACKGROUND: Peripheral blood (PB) smear review is an essential component of the diagnostic workup for hematological disorders. Laboratory-initiated PB smear reviews (LIRs) are performed based on predefined criteria involving complete blood count (CBC) parameters, analyzer-generated flags, and clinical information. However, nationwide data on LIR practices, workloads, and reimbursements are limited. Therefore, we investigated the status of LIR practices in Korean institutions. METHODS: A nationwide survey of medical institutions in South Korea was conducted between October and November 2025. Responses covering LIR criteria, analyzer flag utilization, workload, reporting, and reimbursements were collected from 103 institutions. Workload was assessed using case- and time-based approaches. RESULTS: Among the participating institutions, 94.1% used predefined LIR criteria. Analyzer-generated flags were the most frequently applied criteria (95.8%), followed by CBC (85.4%) and automated differential count (85.4%) parameters. Compared with the 2010 Korean nationwide survey, supplementary criteria for reticulocyte count, clinical information, and delta checks were less frequently used. The numerical thresholds exhibited notable inter-institutional variability. The operational burden was concentrated on technologist-performed workflows, with median monthly times of 4,825 and 575 min for technologists and hematology specialists in large academic centers, respectively. Most institutions (79.4%) did not claim reimbursements for LIRs. CONCLUSIONS: LIR practices in Korea have evolved toward simpler, analyzer-centered workflows; however, variability persists in terms of review criteria, workload, reporting, and reimbursements. Therefore, updated consensus recommendations and reimbursement policies are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improving laboratory criteria to reduce unnecessary peripheral blood smear reviews by pathologists.Laboratory medicine · 2026
- 283 Clinical Value of Physician-Ordered Peripheral Blood Smear ReviewsAmerican Journal of Clinical Pathology · 2026
- Proposal of a Diagnostic Workflow for Peripheral Blood Smear Testing Based on Complete Blood Count Flag Analysis.Clinical laboratory · 2026
- Development and validation of a peripheral blood smear assessment tool using cloud-based full-field digital microscopy.Academic pathology · 2026
- Types and frequency of preanalytical errors occurring in the hematology laboratory at Debre Tabor comprehensive specialized hospital, North Central, Ethiopia, 2025Scientific Reports · 2026
- A-244 Improving Turnaround Time for Pathologist Review of Peripheral Blood SmearsClinical Chemistry · 2026