Loss of the Steep-Axis Flattening Effect in Sutured Clear Corneal Incisions: A Single-Surgeon Vector Analysis.
Eun Jung Jung, Yoon Soo Kim, Youngsub Eom, Jong Suk Song, Dong Hyun Kim
Department of Ophthalmology, Korea University College of Medicine, Seoul, Republic of Korea. · YES Eye Clinic, Seoul, Republic of Korea.
Key points
From the paper's conclusion- In this single-surgeon series of sutured clear corneal incisions, steep-axis incisions did not produce the expected flattening of the incision meridian, and the SIA acted predominantly as torque with a mean steepening effect. Whether the routine suture contributes to this pattern remains to be confirmed by direct sutured-versus-sutureless comparison.
Abstract
PURPOSE: Corneal incisions are conventionally assumed to flatten the incision meridian, and steep-axis incision placement has been advocated to reduce pre-existing astigmatism. We aimed to evaluate whether steep-axis clear corneal incisions actually flatten the incision meridian in a single-surgeon series in which the main incisions were closed with a suture. METHODS: This retrospective study analyzed 345 right eyes that underwent phacoemulsification by a single surgeon using superior (100°) or temporal (190°) clear corneal incisions (2.20 or 2.75 mm), each closed with a single 10-0 nylon suture removed at 1 week. Surgically induced astigmatism (SIA) was calculated by vector analysis and decomposed into a flattening component on the incision meridian and a torque component on the orthogonal meridian. The main analysis was focused on steep-axis incisions, defined as a preoperative steep meridian within ±20° of the incision meridian (superior, n = 96; temporal, n = 66). RESULTS: In steep-axis incisions, the mean flattening effect was negative rather than positive, indicating steepening rather than the intended flattening (superior -0.17 ± 0.56 D, p < 0.001; temporal -0.20 ± 0.73 D, p = 0.059). The perpendicular torque exceeded the flattening effect in all subgroups (superior 0.50 D; temporal 0.40 D), and the SIA meridian deviated from the incision meridian by 52-55° on average. The centroid SIA for the 2.75 mm superior incision was 0.50 D at 41°, consistent across astigmatism types. Individual SIA magnitude was highly variable (0-2.04 D). White-to-white corneal diameter was the only independent biometric predictor of SIA magnitude (β = -0.182, p = 0.027). CONCLUSIONS: In this single-surgeon series of sutured clear corneal incisions, steep-axis incisions did not produce the expected flattening of the incision meridian, and the SIA acted predominantly as torque with a mean steepening effect. Whether the routine suture contributes to this pattern remains to be confirmed by direct sutured-versus-sutureless comparison.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of steep-axis incisions on anterior and posterior corneal astigmatism and higher-order aberrations after cataract surgery.Frontiers in medicine · 2026
- Surgically Induced Astigmatism after Superotemporal and Superonasal Clear Corneal Incisions in Phacoemulsification.Nepalese journal of ophthalmology : a biannual peer-reviewed academic journal of the Nepal Ophthalmic Society : NEPJOPH · 2026
- Effect of On-Axis Incision on Surgically Induced Astigmatism Following Phacoemulsification Cataract Surgery.Journal of the College of Physicians and Surgeons--Pakistan : JCPSP · 2026
- SIA Vector Analysis and Keratometry Prediction in Temporal SICS with 350 µm Scleral Incision Depth.Romanian journal of ophthalmology · 2026
- Vector Analysis of Surgically Induced Astigmatism for Individualized Superior Incision Selection in ICL Surgery: Real-World Outcomes of Corneal and Limbal Incisions Stratified by Preoperative Astigmatism.Journal of ophthalmology · 2026
- Incision-induced astigmatic changes in eyes undergoing simultaneous phakic intraocular lens explantation and phacoemulsificationJournal of Cataract & Refractive Surgery · 2026